Switch, Buttons And Input
Jacks
HOLD/B.L Button
- For holding the reading or control
backlight
S E L Button
- For switching among measuring
functions
REL Button
- The key is the relative value
measurement.
Hz/% Button
- For switching between frequency
and duty measuring functions.
MAX/MIN Button
- For switching between maximum
Instructions manual |
28
15
14
OFF
400A
13
Ω
Hz/DUTY
/%
B.L
Hz
12
HOLD
Press 2 Sec
AUTO-POWER OFF
11
MAX MIN
%
n F
mVA
Mk
Hz
10
20
30
40
INPUT
600V
CAT. III
MAX 1000V
750V
and minimum value measuring
function.
Rotary Selector
- For selecting functions and ranges.
OFF Position
- for turning off the power.
INPUT Jack
- For measuring voltage, resistance,
frequency, duty,capacitance, diode,
and continuity.
COM Jack
- Common input connection for
current, voltage, resistance,frequency,
duty, capacitance, diode, continuity
measurement.
Clamp
- For measuring current
16
17
CAUTION
ACCOR D W ITH
18
POLLUTION D E GR E E 2
600V C AT l ll
IE C 1010 1 I E C 1010 2 0 32
&
19
WAR NING
TO AVOID E L E C TR IC AL
S HOC K D O N OT
OP E R ATE W ITH O P E N
B ATTE R Y C OVE R
DC 1.5VX3, S IZE AAA