ENGLISH
≤
≤
4.
Temperature: -4°
°F
Features:
HOLD
• Use included thermocouple.
5.
Resistance / Capacitance / Diode / Continuity
Resistance Features:
AUTO
AC
A
•
•
Capacitance Features:
AUTO
AC
A
•
• Wait up to 60 seconds for measurement.
•
Diode Features:
AUTO
AC
A
Display shows:
• Forward voltage drop if forward biased.
• "O.L." if reverse biased.
Continuity Features:
AUTO
AC
A
• Display shows resistance.
• Buzzer sounds if less than 60Ω
SYMBOLS USED ON LCD
~
AC Measurement
-
Negative DC Value
Low Battery
H
Hold Active
V
Voltage Measurement
Hz
Frequency in Hertz
F
Capacitance in Farads
Ω
Resistance in Ohms
m
Milli 10
-3
n
Nano 10
-9
1832°
AC
A
PRESS
TO SELECT
Resistance
Diode
Capacitance
Continuity
HOLD
RANGE
Ω
< 40MΩ
Do not measure resistance
on a live circuit.
HOLD
RANGE
F
< 100μF
Safely discharge capacitor before
measurement.
HOLD
HOLD
DC Measurement
Auto Range Active
AUTO
A
Current in Amps
Diode Test
Continuity Test
%
Duty Cycle
F
°
Temperature in Fahrenheit
M
Mega 10
6
k
Kilo 10
3
μ
Micro 10
-6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
400mV
0.1mV
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Overload Protection:
600V DC / AC
Input Impedance:
10MΩ.
AC Voltage Measurement
Range
Resolution
400mV
0.1mV
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Overload Protection:
600V DC / AC
Frequency:
40 to 400Hz
Input Impedance:
10MΩ.
Response:
Averaging
AC Current Measurement
Range
Resolution
4A
0.001A
4A
0.001A
40A
0.01A
400A
0.1A
600A
1A
720A for 60 sec. max
Overload Protection:
50 to 60Hz
Frequency:
Response:
Averaging
Resistance Measurement
Range
Resolution
400Ω
0.1Ω
4kΩ
0.001kΩ
40kΩ
0.01kΩ
400kΩ
0.1kΩ
4MΩ
0.001MΩ
40MΩ
0.01MΩ
Overload Protection:
600V DC / AC
Accuracy
± (0.8% + 2 digits)
± (1.0% + 2 digits)
Accuracy
± (1.0% + 10 digits)
± (1.2% + 10 digits)
Accuracy
≤
± (3.5% + 20 digits)
0.5A
± (3.0% + 10 digits) > 0.5A
± (3.0% + 10 digits)
± (2.5% + 10 digits)
± (1.5% + 5 digits)
Accuracy
± (1.2% + 2 digits)
± (2.0% + 5 digits)