Interruption Of Work; Taking Out Of Operation And Cleaning - Titan Compact 170 Manual Del Usuario

Ocultar thumbs Ver también para Compact 170:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
Compact 170

Interruption of Work

Be sure to follow the Pressure Relief Procedure when shutting the unit off for any purpose.
This procedure relieves the pressure from the spray hose and the gun.
Danger
Switch the device off and remove the power plug.
Put the spray gun in a plastic bag and seal so that it is air-tight.
Wet paint surface in paint container with a little water to prevent a skin from forming.

Taking Out of Operation and Cleaning

Proper cleaning is the prerequisite for problem-free operation of the paint application device. no warranty claims are
accepted in case of improper or no cleaning.
Do not clean the device or accessories with flammable solvents with a flash point below 21 °C.
Danger
i
Always clean the device as soon as you have finished operation.
Dried-on coating substance makes cleaning more difficult.
1. Perform Pressure Relief Procedure.
2. Secure the spray gun.
3. Remove the nozzle holder from the spray gun. (Fig. 18)
4.
Put the suction hose and return flow pipe into a container full of water or suitable cleaning solution.
5.
Turn the switch to the SPRAY position and set maximum pressure.
6.
Hold the spray gun at the edge of an empty container. (Fig.19)
Ground gun with a metal container if flushing with flammable solvent.
Danger
7. Release the gun and keep the trigger pressed until only clear liquid emerges from the gun.
8. Switch the device off and remove the power plug.
9.
Turn the switch into the PRIME position (vertical).
10.
Pull the trigger to relieve the pressure.
11. Secure the spray gun.
12.
Remove spray gun from the paint hose using adjustable wrenches.
13.
Pull t
he hoop guard forward and unscrew the gun housing with a wrench. (Fig. 20)
14.
Remove the gun filter. Clean it and the nozzle with a soft brush and a suitable detergent.
15.
Remove the nozzle (1), plain washer (2) and the mounting (3) from the nozzle holder (4) and clean all parts thoroughly.
(Fig.21)
16.
Trickle a few drops of oil into the gun. (Fig.
17.
Replace the cleaned filter in the gun housing with the conical side forwards and screw the gun housing to the spray gun
again. (Fig. 23)
18.
Replace the mounting and the plain washer in the nozzle holder.
Screw the nozzle holder onto the gun.
19.
Detach the suction hose from the basic unit.
20.
Disconnect the return line by pushing the blue lock ring upwards and pulling the hose downwards at the same time.
21.
Wipe off the exteriors of both hoses.
22.
Carefully remove the filter disc (1) from the suction filter using pliers. (Fig. 24)
23.
Clean the filter disk thoroughly under running water.
24.
Remove the high pressure hose from the basic unit with a wrench.
25.
Depress the automatic lubricator button 2 or 5 times. (Fig. 26)
26.
Insert the power plug.
27.
Hold a cloth in front of the hose connection and switch the device on for approx. 5 seconds. (Fig. 27)
This procedure preserves the pump.
22)
GB
23

Publicidad

Tabla de contenido
loading

Tabla de contenido