13. Adjusting the temperature limits

Warning!
If the hot water supply temperature is above 45°C, the - temperature limit should be
adjusted.
Failure to observe this instruction can result in injuries due to scalding.
13.1 Remove the pressure cap (see
13.2 Carefully lever off the stop ring with a screwdriver and pull off the gear teeth by hand.
13.3 Put the pressure cap in place and trigger the fitting.
13.4 Turn the pressure cap until the desired maximum water temperature is reached.
13.5 Slide the stop ring onto the gear teeth so that the stud on the stop ring is at the right-
hand end stop of the housing.

Important!

When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove (see
13.6 Reassemble in reverse order.

14. Maintenance and care

The fitting must be checked and maintained at regular intervals, depending on the
water quality and in accordance with the local conditions and rules and regulations
applicable at the site.
Maintain the following components:
• Filters (see
• Flow rate regulator (see
• Non-return valve (see
• Functional element (see
Use suitable cleaning agents which do not attack the fitting in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
Remove the fitting
For some maintenance tasks, the fitting must be removed.
14.1 Use an Allen key to close the water volume regulators (a).
14.2 Trigger the fitting.
14.3 Loosen the cap nuts (b).
14.4 Remove the fitting.