Appendix 1: Technical data
Model
Nominal output
Flue connection (diameter)
Weight
Recommended fuel
Fuel property, max. length wood
Mass flow of flue gasses
Temperature increase measured in
the measuring section
Temperature measured at appliance
exit
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
)
2
CnHm emission (13%O
)
2
Particulate emission (13%O
Particulate emission in accordance
with NS3058-NS3059
Efficiency
Subject to change because of technical improvements
45M
9 kW
150 mm
155 kg
Wood
45 cm
8.5 g/s
273 °C
410 °C
12 Pa
0.09%
91 mg/Nm³
96 mg/Nm³
)
13 mg/Nm³
2
-
75.30%
45M
45M
9 kW
9 kW
150 mm
150 mm
155 kg
155 kg
Coal
Brown coal
12/22 - 20/30
3" - 6" - 7"
7.6 g/s
8.8 g/s
282 °C
286 °C
389 °C
395 °C
12 Pa
12 Pa
0.08%
0.07%
86 mg/Nm³
158 mg/Nm³
136 mg/Nm³
109 mg/Nm³
4 mg/Nm³
13 mg/Nm³
-
-
79.50%
75%
45C
9 kW
150 mm
160 kg
Coal
12/22 - 20/30
7.6 g/s
282 °C
389 °C
12 Pa
0.09%
86 mg/Nm³
136 mg/Nm³
4 mg/Nm³
-
79.50%
23