Power Connection - Bosch REXROTH MAD S6 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

IndraDynA_ATEX

Power Connection

DOK-MOTOR*-IDYN*A*ATEX-IB02-D5-P
Proceed as follows to connect the power cable in the terminal box of the
motor:
1. Unscrew and remove the 4 fastening bolts on the lid (1) of the
terminal box and open the lid.
(1):
Lid
(3):
PE connection
(5):
U-V-W power connection
(7):
Purging connection port
Fig. 5-6:
Terminal box
2. Remove the screw plug (4) of the metric screw on the side of the
terminal box and guide the power cable through this opening and into
the terminal box.
3. Attach the power cable to the terminal box. Use the cable gland
located on the power cable.
4. The wires are arranged according to Fig. 5-7.
Note:
Ensure that the wires are sufficiently clamped inside the wire
end ferrules. The connections of the ring terminals must be
tightened with:
• Thread M6 ! 4 Nm
• Thread M8 ! 9 Nm
• Thread M10 ! 18 Nm
5. Fasten the lid (1) of the terminal box using all 4 fastening bolts
secured with Loctite 243. Before tightening the bolts, make sure that
the gasket (2) between the lid and the terminal box housing is
correctly positioned.
Notes:
• The brake connections are assigned only if the motor was
manufactured with the "brake" option.
Operating Instructions
MAx_Power_Box_ATEX.eps
(2):
Gasket
(4):
Cable entry
(6):
Terminal strip
(8):
Through hole
5-9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rexroth maf s6 serieRexroth mad m6 serieRexroth maf m6 serie

Tabla de contenido