3.2 ADVANCED PROGRAMMING FUNCTIONS
Display
Advanced Function
bo
TIME OF MAXIMUM POWER AT STARTING:
You can set the starting time. During start the motors work at maximum power
for starting the movement.
Adjustable from
selected with
cS
FINAL STROKE WHEN CLOSING (RAM STROKE) (NOT displayed if
function
Lets you enable/disable the ram stroke on swing-leaves.
The ram stroke facilitates latching of the electric lock by activating the motors
at maximum power during final closing.
Y
= enabled (for 2 sec)
no
= disabled
In case of systems with an absolute encoder, to enable this function
a setup must be performed using the automatic leaf stop on the
mechanical contact point.
rS
REVERSE STROKE WHEN OPENING displayed if function
Lets you enable/disable the reverse stroke on leaf doors.
The reverse stroke facilitates unlatching of the electric lock. When the auto-
matic system is closed, before starting to open, the motors give a brief push
to close.
Y
= enabled (for 2 sec)
no
= disabled
In case of systems with an absolute encoder, to enable this function
a setup must be performed using the automatic leaf stop on the
mechanical contact point.
Od
DELAY FOR OPENING LEAF (visualised only with the function
You can set the delay time for starting leaf 2 opening with respect to leaf 1, in
order to avoid overlapping of the two leaves.
Adjustable from
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
e.g.: if the display shows
SAFEzone RETROFIT KIT
00
10
to
sec, in 1-second steps (ignoring the power level
F1
F2
and
).
FC
1
=
):
00
59
to
sec, in 1- second steps.
1.3
minutes.
1.2
, the time is 1 min and 20 sec.
8
Default
01
no
FA
1
no
=
):
Mn
2
02
=
):
532037 - Rev. B