FAAC SAFEzone RETROFIT KIT Guía Rápida De Inicio página 29

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
4. TIME LEARNING - SETUP
When the board is powered, if a SET-UP has never been performed or if the board requires it,
flashes on the display indicating that a SET-UP must be performed.
The connected accessories are always registered during SET-UP.BUS-2EASY The
BUS-2EASY encoders registered during the SET-UP must then be enabled via the
function (BASIC Programming).
Perform the SET-UP as follows:
All safety devices are disabled during SET-UP! Therefore, perform the operation and
prevent any transit in the leaf movement area.
If a system without an encoder is installed, the leaves will require mechanical stops.
1. Access BASIC programming and go to the tL function, and -- will appear when the F button is
released.
2. Verify that the gate leaves are closed. Otherwise, proceed as follows:
- Keep the -/R2 button pressed to close leaf 2
- Keep the +/R1 button pressed to close leaf 1
If the corresponding leaf opens when the +/R1 and/or -/R2 buttons are pressed,
disconnect the power and invert the phase wires of the corresponding motor on
the J2 terminal board, (terminals 2-3 for the leaf 1 motor and terminals 5-6 for
the leaf 2 motor).
3. With the gate leaves closed, launch the SET-UP procedure by keeping buttons
S1
flashes on the display (approx. 3 sec).
+
and - . Leaf 1 begins its opening movement.
4. Release
Operation WITH Encoder: leaf 1 will stop as soon as it reaches the mechanical stop. If there is no
mechanical stop, stop the leaf movement at the desired point by sending an OPEN A pulse.
S2
will flash on the display (only if 2 motors have been selected): leaf 2 begins its opening movement.
5.
Operation WITH Encoder: leaf 2 will stop as soon as it reaches the mechanical stop. If there is no
mechanical stop, stop the leaf movement at the desired point by sending an OPEN A pulse.
S3
will flash on the display (only if 2 motors have been selected): leaf 2 begins its closing movement.
6.
Operation WITH Encoder: leaf 2 will stop as soon as it reaches the mechanical stop. If there is no
mechanical stop, stop the leaf movement at the desired point by sending an OPEN A pulse.
S4
will flash on the display: leaf 1 will begin its closing movement.
7.
Operation WITH Encoder: leaf 1 will stop as soon as it reaches the mechanical stop. If there is no
mechanical stop, stop the leaf movement at the desired point by sending an OPEN A pulse.
8. The board will automatically exit the programming menu and will display the status of the automated
00
system (
) as confirmation that the SET-UP procedure has been completed correctly. If the
procedure is not completed correctly,
SET-UP procedure must be performed.
SAFEzone RETROFIT KIT
S0
will start flashing on the display, indicating that a new
13
S0
En
+
and - pressed until
532037 - Rev. B

Publicidad

Tabla de contenido
loading

Tabla de contenido