FAAC SAFEzone RETROFIT KIT Guía Rápida De Inicio página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Display
Advanced Function
r1
LEAF 1 DECELERATION:
You can adjust the deceleration space as a percentage of the total travel of
leaf 1.
Adjustable from
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
r2
LEAF 2 DECELERATION (visualised only with the function
You can adjust the deceleration space as a percentage of the total travel of
leaf 2.
Adjustable from
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
PF
PRE-FLASHING:
You can enable/disable the pre-flashing. Pre-flashing duration = 3 sec.
You can choose:
no
= disabled
OC
= pre-flashing before each movement
CL
= pre-flashing before a closing movement
OP
= pre-flashing before an opening movement
PA
= pre-flashing only at the end of the pause time
Ph
CLOSING
The intervention of closing photocells causes the reversing of automated
system (opening).
You can choose:
Y
= operate the reversal only after the photocells are released
no
= operate the reversal immediately
Ad
ADMAP
FUNCTION:
Allows operation in compliance with French regulation NFP 25/362.
Y
= enabled
no
= disabled
EC
ANTI-CRUSHING SENSITIVITY (visualised only with the function
Y
=
):
Varying this function varies the amount of time after which, in case of obsta-
cle, the board commands reversal of the leaves, or it will command a stop
if the leaves are in the contact point search space (see the parameter
The fourth consecutive obstacle detected in the same direction and position
will be defined as a contact point and the leaf will stop in that position.
00
= minimum sensitivity (maximum time before reversal)
10
= maximum sensitivity (minimum time before reversal)
SAFEzone RETROFIT KIT
00
99
to
%, in 1% steps.
00
99
to
%, in 1% steps.
PHOTOCELLS:
9
Default
20
Mn
2
20
=
):
no
no
no
En
05
rB
).
532037 - Rev. B