• Loosen the sensor support screws, adjust the opening and closing position of the sensors using
the notches as a guide, and tighten the screws.
• Secure the cables to the appropriate supports using cable straps.
See the instructions attached to the limit switch kit for additional information.
6.8 Remote release
Gear-motors PWR25H and PWR35H are prepared for the use of a cable operated remote unlocking
device. If necessary (single input or standard release on the operator not accessible) the remote
release device can be installed in the lower part of the operator.
See the instructions attached to the device for additional information.
The standard manual release functions normally, whereas the release will only be pos-
i
sible from the remote release device, while the reset will have to be performed using the
standard manual release.