The water temperature is is only shown when there is water circulation or it stopped recently. It
can be shown:
In grades (ºC or ºF)
----- when the Temperature sonde fails.
"
" If the confidence of the reading is low
***** Equipment stopped because maximum defrost time
TECHNICAL SCREEN
Only available with the technical shortcircuit.
T Defrost 1 (sonde
2)
T Defrost 2 (sonde
3)
Compressor:
CM
Compresor working
TP
Waiting until reach minimum time compressor stopped
--
Compressor stopped
TM
Waiting until reach minimum time compressor working
Error:
Shown number correspond to the addition of next errors:
3
Pahses failure.
4
Pressure switch failure.
4
Water temperature sonde error (sonde 1)
9
Defrost 1 sonde error. (sonde 2)
17
Defrost 2 sonde error. (sonde 3)
33
Defrost time error.
65
Flow error.
General Status:
FX
Waiting for water flow.
DF
Defrosting
CM
Compressor on.
OK
Water Temperature OK.
EV
Waiting for valid T because of lack of water flow.
--
System stopped
FG
System stopped because of error or alarm
ND
Equipment stopped because maximum defrost time ( Max-Def) and waits until
reach the auto reset time (Rea-Def).
Defrost:
Depending on AUX we can select the defrost control with 1 or 2 sondes (Sonde 2
default).
Heat puma reaches defrost status when the inicial defrost temperature (Ini-Def) is
reached
It will be defrosting until both sondes reach Fin-Def and Min-Def is reached.
T Water
(sonde 1)
Error water reading
General status
ENGLISH
Compressor
Error