Astralpool CANCUN Serie Manual Técnico. Puesta En Marcha Y Funcionamiento página 43

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The water temperature is is only shown when there is water circulation or it stopped recently. It
can be shown:
In grades (ºC or ºF)
----- when the Temperature sonde fails.
"
" If the confidence of the reading is low
***** Equipment stopped because maximum defrost time
TECHNICAL SCREEN
Only available with the technical shortcircuit.
T Defrost 1 (sonde
2)
T Defrost 2 (sonde
3)
Compressor:
CM
Compresor working
TP
Waiting until reach minimum time compressor stopped
--
Compressor stopped
TM
Waiting until reach minimum time compressor working
Error:
Shown number correspond to the addition of next errors:
3
Pahses failure.
4
Pressure switch failure.
4
Water temperature sonde error (sonde 1)
9
Defrost 1 sonde error. (sonde 2)
17
Defrost 2 sonde error. (sonde 3)
33
Defrost time error.
65
Flow error.
General Status:
FX
Waiting for water flow.
DF
Defrosting
CM
Compressor on.
OK
Water Temperature OK.
EV
Waiting for valid T because of lack of water flow.
--
System stopped
FG
System stopped because of error or alarm
ND
Equipment stopped because maximum defrost time ( Max-Def) and waits until
reach the auto reset time (Rea-Def).
Defrost:
Depending on AUX we can select the defrost control with 1 or 2 sondes (Sonde 2
default).
Heat puma reaches defrost status when the inicial defrost temperature (Ini-Def) is
reached
It will be defrosting until both sondes reach Fin-Def and Min-Def is reached.
T Water
(sonde 1)
Error water reading
General status
ENGLISH
Compressor
Error
43