Normal ambient conditions for operation are:
Air temp. installation:.................16º C
Water temp. installation............24ºC
Humidity:....................................70%
The limits established for working conditions in order to guarantee the proper operation of
the equipment are:
Minimum air temp. installation: 8ºC
Maximum temperature of pool water: 37ºC
Temperature below this will activate the alarm.
The operating conditions will affect the output of the equipment.
11. REQUIREMENTS AND PROCEDURES
It is important that the equipment be installed on stable, horizontal ground.
Always place the equipment vertically and far away from dangers of inundation. If not, the
warranty will be voided.
Like any other electrical equipment, the dehumidifier should be installed more than 2
meters, horizontally, away from the pool (Volume 2) and 2,5 meters, vertically, away from
the pool.
The heat pump should be installed more than 2,5 meters, vertically, away from the pool.
During operation, condensed water will appear, produced by the passing of air through the
evaporation unit. For this, the machine is equipped with a drainage tube on the base. Please plan
ahead for the drainage.
The air inlets and outlets should be free of obstruction. Obstacles should be maintained at a
distance. To avoid rusting or other corrosive processes the machine can not be installed in an acid
or alkaline ambient.
ENGLISH
48