Care and Cleaning (cont.)
For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care &
Cleaning information, call 1-800-456-4537.
Troubleshooting
NOTE: For service parts information, visit your product page at www.kohler.com/serviceparts.
Small Children
The auto flush and bidet features require a sensor located under the seat to be enabled. Small
children may not be tall enough (approximately 48" (1.2 m)) to activate the sensor. The bidet and
autoflush features will not function correctly when this sensor has not been activated.
General
Symptoms
1.
The toilet has no power.
2.
The toilet does not flush
but has power.
The toilet has power, does
3.
not respond.
4.
No water comes from the
bidet wand or it has a
weak stream when it is
activated.
The heated seat is not
5.
warm at all or it is not as
warm as desired.
Kohler Co.
Probable Causes
A. The power is not turned on.
B. The power cord is not
connected.
C. The GFCI or RCD is tripped.
A. There is no water being
supplied to the toilet.
B. The pump connection has not
been made properly.
C. The level switch is not properly
connected.
D. The actuation assembly does not
work.
A. The actuation switch is not
properly connected.
B. As the toilet is powering off,
before the prompt sound has
stopped, the power was turned
on again.
A. The water supply stop is closed
or only partially open.
B. The inlet hose from the water
supply stop to the toilet is
kinked or looped too tight.
C. Seat sensor does not detect the
user.
D. The water supply screen is
blocked or damaged.
A. The heated seat feature is not
enabled.
B. The temperature setting is too
low.
17
Recommended Action
A. Press the "Power" icon on the
manual control panel.
B. Connect the power cord.
C. Reset the GFCI or RCD (if
applicable).
A1. Open the water supply stop all the
way.
A2. The overflow sensor is not
functioning properly.
B. Check the pump connection.
Reconnect properly.
C. Check the level switch connection.
D. Replace the actuation assembly.
A. Check the actuation switch
connection.
B. After turning the power off wait
until the prompt sound has ended
before turning the power back on.
A. Open the water supply stop all the
way.
B. Remove the kink in the hose or
make the loop wider.
C. Small children may not be
detected. Adjust the sitting
position. The sensor may have
difficulty with fabric or other
objects. The sensor is designed to
sense skin.
D. Service the filter following the
instructions in the Homeowners
Guide.
A. Activate the heated seat feature
using the remote control.
B. Adjust the heated seat temperature
using the remote control.
1221754-5-B