3 Setting Up
30
2. Press the SETUP control briefly. The display will change as follows:
3. Turn the SETUP control CW or CCW to select the same Preset as the one you selected on the first
receiver. Preset names are sorted alphabetically.
4. Press the SETUP control briefly. The "GROUP" label on the display will start flashing.
5. Turn the SETUP control CW or CCW to select the same Group as the one you selected on the first
receiver.
6. Press the SETUP control briefly. The receiver will automatically find the next clean frequency.
As soon as the receiver has found an interference-free frequency, the Subchannel number assigned
to this frequency will be displayed. The SETUP control will not respond to turning. The Preset Name,
Group, and Subchannel fields will be flashing:
Clean frequencies are frequencies where the receiver finds no RF signal or an RF signal whose level
Note:
is lower than the current threshold setting.
Low-number Subchannels are less susceptible to intermodulation than higher-number Subchannels.
Note:
7. Press the SETUP control briefly. The display will change as follows:
• To save your setting, press the SETUP control briefly. The display will revert to the Auto Channel Setup
screen.
• If you'd rather not save your setting, turn the SETUP control CW or CCW. The display will change as
follows:
- Press the SETUP control briefly. The display will revert to the Auto Channel Setup screen.
8. Tune the transmitter assigned to the receiver to the same frequency that you selected on the receiv-
er and switch power to the transmitter on.
9. If the receiver finds no clean frequency, the display will look like this:
- Press the SETUP control briefly. The display will change as follows:
• To try again, press the SETUP control briefly and repeat steps 2 through 8 above.