Possible Combinations Of Base Plates And Cards; Identifying The Modules; Material Number For Bus Coupler; Material Number For Valve System - Emerson AVENTICS AES PROFINET IO Descripción Del Sistema

Acoplador de bus aes/controladores de válvula av
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90

12.2.9 Possible combinations of base plates and cards

Valve driver boards, 4x, are always combined with two 2x base plates.
Table 17 shows the possible combinations of base plates, pneumatic supply
plates, electrical supply plates, and transition plates with various valve driver
boards, bridge cards, and supply boards.
Table 17: Possible combinations of plates and cards
Base plate
Base plate, 2x
Base plate, 3x
Two base plates, 2x
Pneumatic supply plate
Transition plate and pneumatic supply plate
Electrical supply plate
1)
Two base plates are linked with a valve driver board.
The boards in the AV-EP base plates are installed permanently and can
therefore not be combined with other base plates.

12.3 Identifying the modules

12.3.1 Material number for bus coupler

12
AES-D-BC-XXXX
R4120XXXXX
The bus coupler can be clearly identified using its material number. When ex-
changing the bus coupler, you can use the material number to reorder the same
unit.
The material number is printed on the name plate (12) on the back of the device
and on the top below the identification key.

12.3.2 Material number for valve system

The material number for the complete valve system (46) is printed on the right
end plate. You can use this material number to reorder an identically configured
valve system.
Note that, after a valve system conversion, the material number still refers to
u
the original configuration (see "Conversion documentation").

12.3.3 Identification key for bus coupler

AVENTICS™ AES PROFINET IO | R412018140-BAL-001-AH | English
Circuit boards
Valve driver board, 2x
Valve driver board, 3x
1)
Valve driver board, 4x
Short bridge card or
UA-OFF monitoring board
Long bridge card
Supply board
7291
46
1
The identification key (1) on the top of the AES series bus coupler for
PROFINET IO is "AES-D-BC-PNIO" and describes the unit's main characteristics.

12.3.4 Equipment identification for bus coupler

The bus coupler requires a unique ID to enable the clear identification of the unit
within the system. The two equipment identification fields (4) on the top and
front of the bus coupler are available for this purpose.
Label the two fields as shown in your system diagram.
u

12.3.5 Bus coupler rating plate

The rating plate is located on the back of the bus coupler. It contains the follow-
ing information:
47
48
AES-D-BC-XXXX
49
R4120XXXXX
50
51
52
53
54
55
Fig. 15: Bus coupler rating plate
47
Logo
49
Mat. no.
51
Power supply
53
Serial number
55
Country of manufacture
57
CE mark

12.4 PLC configuration key

12.4.1 PLC configuration key for the valve zone

The PLC configuration key for the valve zone (59) is printed on the right end
plate.
The PLC configuration key specifies the sequence and type of electrical compo-
nents based on a numerical/alphabetical code. The PLC configuration key con-
sists solely of numbers, letters, and dashes. There are no spaces between the val-
ues.
In general:
• Numbers and letters refer to the electrical components.
• Each digit corresponds to one valve driver board. The number's value refers to
the number of valve positions for a valve driver board.
4
58
57
7291
56
48
Series
50
MAC address
52
Manufacture date (FD) with format
"FD: <YY>W<WW>"
54
Manufacturer's address
56
Data Matrix code
58
Internal plant ID
59
40

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

R412018223R412088223

Tabla de contenido