Electrical Installation - Campbell Hausfeld VT639100 Manual De Instrucciones Y Lista De Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions and Parts Manual
Installation
(Continued)
2. Insert mounting bolts. Use 3/8 inch x 5 inch wedge anchors
(not included) to secure the unit. Place nut and washer on
bolt. Thread nut onto bolt until tops are fl ush. Strike bolt
with hammer until nut and washer are setting on top of
the compressor foot.
Tighten nut using ratchet with a 9/16 inch socket until
anchor is set (using installation torque specifi cations of
bolt being used). Loosen nut to leave a 1/16 inch (1.6 mm)
gap for stress relief during unit operation (see Figure 4).
PIPING
Never use plastic (PVC) pipe for
compressed air. Serious injury or death
could result.
Any tube, pipe, or hose used must have a pressure rating
higher then 150 psi. Minimum recommended pipe size:
- up to 50 feet long use 1/2 inch
- greater than 50 feet long use 3/4 inch
Larger diameter pipe is always better.

Electrical Installation

All wiring and electrical
connections must be performed
by a qualifi ed electrician familiar with industrial
motor controls. Installations must be in accordance
with local and national codes.
Disconnect, tag and lock out
power source, then release
all pressure from the system before attempting
to install, service, relocate or perform any
maintenance.
Overheating, short circuiting and fi re
damage will result from inadequate
wiring.
GROUNDING
This product must be grounded. A properly sized cord with a
ground conductor and plug may also be installed by the user.
Improperly grounded motors are
shock hazards. Make sure all the
equipment is properly grounded.
WIRING
Local electrical wiring codes differ from area to area. Source
wiring, plug and protector must be rated for at least the
amperage and voltage indicated on the motor nameplate, and
meet all electrical codes for this minimum. Use a slow blow
fuse type T or a circuit breaker.
Damage to the motor from improper
electrical voltage or connection will void
the warranty.
You will need the following for proper installation:
1. A 240 Volt double pole circuit breaker.
2. A voltage meter.
Confirm proper voltage - must be performed by a qualified
electrician.
www.campbellhausfeld.com
Metal Plate
Rubber Pad
Figure 4
Figure 5
230 / 240
Volts
Figure 6
120 Volts
Figure 7
6
Concrete Anchor
1/16 inch (1.6 mm)
Line
Line
Ground
Line