Installation
(Continued)
Electrical Installation (Continued)
Remove the pressure switch cover by loosening the screw
(see Figure 8). Use a Phillips screwdriver (not included).
Familiarize yourself with the pressure switch once cover is
removed (see Figure 9).
Remove ground screw. Install strain relief on pressure switch.
DO NOT tighten strain relief on power cord until wiring is
complete. Insert the bare wires (black, white, bare/green)
through the strain relief.
Attach bare/green ground wire fi rst to ground screw on
pressure switch body.
Look for the "Line" markings on pressure switch. Install Line
wires and tighten terminal screws (see Figure 10).
Tighten strain relief nut. Place a fl athead screwdriver (not
included) into raised notch and tap screwdriver with hammer
(not included) until tight (see Figure 11).
Tighten strain relief screws to hold power cord securely (see
Figure 11).
Replace the pressure switch cover (knob must be in the same
position as when removed to sit correctly in place). Tighten
the pressure switch screw with Phillips screwdriver. Check that
switch is in the OFF position.
Minimum wire sizes (most meet all codes)
Up to 75 feet long
Greater than 75 feet
Figure 8
Figure 9
12AWG
10AWG
Figure 10
Figure 11
7
Line Terminal
Terminal Screw
Black Line Wire
Power Cord
Strain Relief
Strain Releif Nut
www.campbellhausfeld.com
VT639100
Screw
Motor Terminal
Ground
Screw
White Line Wire
Bare/green
Ground
Wire
Strain
Relief
Screw