DINAMIC 1.1
EN
Symptom
• The display shows E2, the equipment goes
off automatically and the display shows
error E2 until the anomaly is repaired. For
the display to stop showing E2, disconnect
the cut-out of the power supply cable to the
battery.
• When turning on the equipment or
during operation, the display shows E3
(compressor failure).
• When turning on the equipment or
during operation, the display shows E5
(compressor failure).
• When turning on the equipment or
during operation, the equipment gives
out intermittent beeps and the display
shows E6 (antifreeze sensor failure). The
equipment
disconnects
but the display shows error E6 until the
anomaly is repaired. For the display to
stop showing E6, disconnect the cut-out of
the power supply cable to the battery.
• Blower or electrofan blocked or short-
circuited.
• Excess load.
• Compressor defective or failed.
• Control module failure.
• Failure through heating of the control
module.
• Poor connection in antifreeze sensor
cables or terminals.
automatically,
• Antifreeze sensor disconnected or failed.
12
Air conditioning for vehicles
Cause

Publicidad

loading