DiSpLAy
FuMeS FAiLure
FuMeS prOBe
ALArM
FuMeS OverteMper-
Ature
cLeAn
cHeck-up 1 - 2
(1= At StArtup)
(2= At WOrk)
Depr ALArM
nO
ignitiOn
BLAck-Out nO ign.
nO peLLetS
cOOLing StAnD-By
Depr SenSOr
DAMAge
Auger cOntrOL
ALArM
56
expLAnAtiOn
Indicates the presence of an alarm.
Fault correlated to the flue gas
exhaust motor.
Fault correlated to the fumes probe.
The flue gas temperature has
exceeded 310°C
The combustion chamber or burn pot
bottom are dirty.
The door is not closed correctly.
The ash drawer is not closed
correctly.
The depression sensor is faulty.
The flue exhaust pipe is blocked.
Incorrect installation
The mechanical depression sensor
has tripped
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
No current during the ignition phase.
In the work phase, the t° of the flue
gases has dropped below factory
parameters
attempt to release the alarm with
stove still in cooling mode.
Component disconnected or faulty
anomalous functioning
of pellet feeding
ALArMS
on: indicates the presence of an alarm
off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 3 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
The restoration operations must be carried out by an authorised
technician.
The restoration operations must be carried out by an authorised
technician.
Check pellet flow (see "Pellet feed adjustment").
Check that the machine is clean, including the flue route.
Do not rest cloths on the machine.
other restoration operations must be carried out by an authorised
technician.
Make sure the holes at the burn pot bottom are completely free.
Check cleanliness of the fumes pipe, of the sensor in the primary
air channel and the combustion chamber.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
other restoration operations must be carried out by an authorised
technician.
Contact after-sales centre
Check for the presence of pellets in the feed-box.
adjust pellet flow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
other restoration operations must be carried out by an authorised
technician.
Take the stove to oFF conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
other restoration operations must be carried out by an authorised
technician.
Check for the presence of pellets in the feed-box.
regulate the pellet flow.
other restoration operations must be carried out by an authorised
technician.
Every time the stove displays one of the alarms listed above it will
switch-off automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and aTTE alternately on the display.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
Contact after-sales assistance
Contact after-sales assistance
engLiSH
SOLutiOn