Check
A) Main gas line to manifold connection (1) .
B) Rotisserie (I .R . Burner) gas line connection (2) .
C) Bulkhead to regulator connection and regulator to hose connection (3) .
D) Side burner hose to bulkhead connection (4) .
m WARNING: If there is a leak at connection (1, 2, 3, or 4),
retighten the fitting with a wrench and recheck for leaks with
soap and water solution. If a leak persists after re-tightening
the fitting, turn off the gas. DO NOT OPERATE THE GRILL.
Contact the Customer Service Representative in your area
using the contact information on our web site. Log onto
www.weber.com
.
®
E) Side burner hose to quick disconnect connection, side burner line to valve and
orifice connections (5) .
F) Hose to quick disconnect connection (6) .
G) Valves to manifold connections (7) .
m WARNING: If there is a leak at connections (5, 6, or 7), turn
off the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your area using the
contact information on our web site. Log onto
www.weber.com
.
®
When leak checks are complete, turn gas supply off at the source and rinse connections
with water .
Reinstall Control Panel
Parts required: control panel, screws, and burner control knobs .
A) Hook the top edge of the control panel onto the control panel brackets on either side
of the front of the cookbox .
B) Line up screws with screw holes on both the control panel bracket and the frame .
C) Tighten screws .
D) Place corresponding control knobs onto the valve stems .
Reinstall Side Burner Cabinet Water Deflector
Tools required: Phillips screwdriver .
A) Push front edge of water deflector up on an angle into side burner cabinet . The front
edge rests on the lip on the underside of the table . Pivot rear edge of deflector up
and rest on rear lip of table .
B) replace screw securing side burner cabinet water deflector .
GAS INSTRUCTIONS
◆
The grill illustrated may
have slight differences
than the model purchased.
7
1
3
4
5
2
6
WWW.WEBER.COM
®
19