Filling the coolant container
(figure 5).
Do not use the magnetic core drill unit when
the cooling-lubricant system is defective. Each
time before operating, check for tightness
against leaks and for cracks in the hoses. Pre-
vent liquids from entering or penetrating elec-
trical components.
Unscrew the hand pump from the coolant
container.
Only use a coolant-lubricant emulsion (oil in
water) as the cooling agent.
Observe the manufacturer's instructions on
coolant.
Screw the hand pump back onto the coolant
container.
Connecting the coolant hose
(figure 6).
Connect the coolant hose.
Fig. 5
Hand pump
3.
1.
Fig. 6
1.
Coolant hose
Coolant container
2.
Coolant
container