Descargar Imprimir esta página

Fein Slugger AJMU137 PMQW Serie Instrucciones De Uso página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000282-002.book Page 19 Tuesday, December 5, 2017 10:35 AM
For switching the magnet ON
(figure 10).
Pay attention that the set-up surface for
the magnetic foot is flat, clean, rust-free
and ice-free. Remove varnish, putty/filler lay-
ers and other materials. Prevent an air gap
between the magnetic foot and the set-up
surface. The air gap reduces the magnetic
holding power.
Do not operate this machine on hot sur-
faces; it could lead to a permanent reduc-
tion of the magnetic holding power.
When working, always use the magnetic
foot; pay attention that the magnetic
holding power is sufficient:
– When the green button on the control
panel lights up permanently, the magnetic
holding power possibly is sufficient and the
machine can be operated with normal feed.
– When the Magnet button on the control
panel flashes, the magnetic holding power
possibly is insufficient and the machine
must be operated with reduced feed.
When working non-magnetic materials, suit-
able FEIN fastening devices, such as vacuum
plates or pipe drilling devices, which are avail-
able as accessories, must be used. Observe
the corresponding operating instructions for
these.
Even when working on steel materials where
the material thickness is below 9 mm, the
workpiece must be made thicker with an
additional steel plate in order to ensure the
magnetic holding power.
The magnetic holding power can be switched
step by step with the hand lever.
For positioning, set the hand lever to the
30 % position; to switch the magnet on, set
the hand lever to the 100 % position.
After approx. 10 minutes without further
actuation, the magnetic core drill unit auto-
matically switches to the sleep function.
Fig. 10
1.
30%
2.
0%
100%
30%
Hand lever,
magnet
100%
1.
2.
0%
100%
30%
10 min
en
19
Sleep

Publicidad

loading