OBJ_BUCH-0000000282-002.book Page 26 Tuesday, December 5, 2017 10:35 AM
en
26
Instructions for core drilling.
Do not stop the drill motor during the drilling
procedure.
Only remove the cutting tool from the hole
while the motor is running.
If the carbide tipped cutter should remain
stuck in the material, stop the drill motor and
carefully turn the carbide tipped cutter out
counterclockwise.
After each drilling operation, remove the
chips and the slug.
Error message/
Meaning
Response of magnet
button
Indicator lights up
Magnetic holding power possi-
green
bly sufficient.
Indicator flashes
Magnetic holding power insuf-
green
ficient.
Indicator flashes red
– Motion sensor has actuated
once or several times
– Overload shut-off has actu-
– Hand lever not set to 100 %
– Buttons for left rotation/right
– Check battery indication
Indicator lights up red
Power tool is defective.
continuously
Indicator does not
– The machine is in sleep func-
light up
– Battery dead or defective
– Power tool is defective
When changing a cutting tool, pay attention
not to damage the cutting edges.
For core drilling in layered material, use a suit-
able Slugger ID cutter.
When core drilling layered material, remove
the core and the chips after having drilled
through each layer.
ated
position
rotation blocked
tion
Do not touch the chips with your bare
hands. Always use a chip hook (6 42 01
001 00 0).
Danger of burning!
Corrective action
Even when working on steel materi-
als where the material thickness is
below 9 mm, the workpiece must be
made thicker with an additional steel
plate in order to ensure the magnetic
holding power.
After malfunction correction, the
power tool can be switched on again.
Send the machine to your Slugger
customer service agent.
– Actuate magnet button (sleep func-
tion is deactivated).
– Check battery indication
– Send the machine to your Slugger
customer service agent.