ASSEMBLY INSTRUCTIONS
120V Configuration
8
LOW VOLT
ORANGE
BROWN
WHITE
Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that
accepts the plug on the product. Make sure your extension cord is not damaged. When using an
extension cord, be sure to use one heavy enough to carry the current your product draws. For lengths
less than 25 ft. 16-3 AWG extension cords is the smallest gauge that can be used. An undersized
cord results in a drop in the voltage and loss of power and overheating. (NOTICE: Table below shows
the correct size to use depending on cord length. When in doubt, use the next heavier gauge. The
smaller the gauge number, the heavier the cord.)
Use of an extension cord may cause excess heat to motor. This could lead to tripped breaker (at
electrical panel) or tripped thermal overload (on compressor motor). If this occurs, eliminate extension
cord and plug compressor directly into electrical outlet. Avoid using extension cords; use longer air
hose(s) instead.
Check with a qualified electrician or serviceman when the grounding instructions are not completely
understood, or when in doubt as to whether the product is properly grounded. Do not modify the plug
provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician. Only
connect the product to an outlet having the same configuration as the plug. Do not use an adapter with
this product.
Voltage
Amp Rating
120V
Range
14-16
LINE 1
1
2
4
3
LINE 2
25 ft.
50 ft.
100 ft.
16
12
10
240V Configuration
HIGH VOLT
BROWN
ORANGE
WHITE
Cord Length in Feet
150 ft.
200 ft.
250 ft.
8
6
6
12
LINE 1
1
2
4
3
LINE 2
300 ft.
400 ft.
500 ft.
4
4
2