Reference Standards - CAME Z 24 Serie Manual De Instalación

Cuadro de mando para motorreductores 24 v
Ocultar thumbs Ver también para Z 24 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
"CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY"
"THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS"
1 Legend of symbols
This symbol indicates sections to be read with particular care.
This symbol indicates sections concerning safety
This symbol indicates notes to communicate to users.
2 Intended use and application
2.1 - INTENDED USE
The ZL180 control panel is designed to control the F7024N, A3024N and A5024N swing gate operators.
The use of this product for purposes other than as described above and installation executed in a manner other than
as instructed in this technical manual are prohibited.
2.2 - APPLICATION
Make sure you respect the distances and cable diameters as shown in "cable types and minimal thicknesses" table.
The overall power of the motors must not exceed 300W.

3 Reference Standards

For its quality processes management Came Cancelli Automatici is ISO 9001:2000 certified, and for its environmental management it is
ISO 14001 certified. Came designs and manufactures entirely in Italy.
This product complies with the following standards: see chapter 13 - Conformity declaration - pag. 19.
4 Description
This product is engineered and manufactured by CAME cancelli
automatici s.p.a. and complies with current safety regulations.
Guaranteed 24 months if not tampered with.
The control panel works on 230V a.c. of power, through the
terminals L-N, 50/60Hz frequency.
Both command and control devices and accessories are 24V
powered. Warning! Accessories must not exceed 34 W overall.
The control unit is fi tted with an amperometric device which
constantly regulates the motor's drive coeffi cient.
When the gate runs into an obstacle, the amperometric sensor
immediately detects an overcharge in the drive and redirects the
gate's direction of movement, and:
(1)
- opens it if it is closing
- closes it if it is opening.
(1)
Warning!: in this case, after 3 consecutive obstacle detections, the gate
will stop open excluding the automatic closing function; for movement to
start again press the command button or use the remote control.
All connections are protected by quick fuses, see table.
The card provides and controls the following functions:
- automatic closing after an open-command;
- pre-fl ashing by the motion indicator;
- obstacle detection when gate is still in any position;
- continual monitoring of photocell operation.
The following command modes are possible:
- open/close;
- open/close and maintained action;
- partially open;
- complete stop.
After detecting an obstacle and depending on the type of
connection used, the photocells may cause:
- reopening of the gate when it is closing;
- partial stop.
Apposite trimmers regulate:
"IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS"
;
- the automatic closing run time;
- the second gate leaf's motion time difference;
- the amperometric device's detection sensitivity, in separately
in terms of normal opening and closing and braking.
Further implemented options:
- controlling of just one gearmotor;
- peripheral speed reduction (for gate leaves of over 3 m);
- option to change opening endpoint fromt Stop to
Deceleration;
- connecting up an electric lock (alternatively to the 2nd
radio channel or the "Open Gate" indicator light) and possibly
adding the "Ram Blow" function.
T ECH N IC AL F EAT U RES
max. rated power 300W
Power draw when idling 85mA
Max power of 24V accessories 34W
Insulation rating II
Protection rating IP54
operating temperature -20 / +55°C
F U SES
protection fuse type
Electronic board (power supply line) 1.6A-F
Accessories 2A-F
Control devices 630mA-F
Power supply 230V - 50/60Hz
Material ABS
Motor/s 6.3A-F

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zl180

Tabla de contenido