CAME Z 24 Serie Manual De Instalación página 27

Cuadro de mando para motorreductores 24 v
Ocultar thumbs Ver también para Z 24 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
The ZL180 is calibrated to the F7024N or A3024N commands for gate
leaves of up to 3 meters.
To command A5024N models (with gate leaves of over 3 m ) and reduce
peripheral speed, do the following:
a) - Set dip switches 1 and 6 to ON (and dip switches 2, 3, 4, 5 to
OFF);
b) - press CH1: the red PROG led will start to blink;
c) - when the led stays on (after about 5 seconds) the procedure is
complete;
d) - set to the dip switches back to OFF (or to the previous position,
which depends on the functions selection, see paragraph 7, page 12).
N.B.: to return to default, follow the same procedure while pressing CH2.
a)
b)
The control panel is set for 2 gearmotors (2 leaved gates).
With only one gearmotor (one-leaved gates; M2 gearmotor), do the following:
a a ) - Set
) - Set dip switches 4 and 6 to ON
dip switches 4 and 6 to ON (and dip switches 1, 2, 3, 5 to OFF); ;
b) - press CH1: the red PROG led will start to blink;
c) - when the led stays on (after about 5 seconds) the procedure is
complete;
d) - set to the dip switches back to OFF (or to the previous position,
which depends on the functions selection, see paragraph 7, page 12).
N.B.: to return to default, follow the same procedure while pressing CH2.
a)
b)
CH1 = A5024N
c)
CH1 = 1 gate leaf
he following:
c)
default
CH2 = A3024N
F7024N
d)
default
CH2 = 2 gate leaves
d)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zl180

Tabla de contenido