The 595 I/S automation system is a hydraulic unit formed of
a motor pump and a piston-rack assembly, which ensures
optimal automation of up-and-over garage doors. It is
mounted on the door by means of accessories.
The system has an adjustable anti-crushing safety system, a
device that stops and locks the door in any position, and a
convenient manual release device to be used in the event
of a power failure or malfunction.
The 595 I/S automation system has been designed and
manufactured for the automation of counterbalanced up-
and-over doors. Figures 1, 2 and 3 show the most commonly
used types of doors. No other use of the system is allowed.

1. DESCRIPTION AND TECHNICAL CHARACTERISTICS

16
4
3
5
6
7
8
9
10
11 12
external release device (optional)
side mounting bracket
upper flange
oil filler plug
oil tank
internal release knob
distribution flange
torque adjustment screws
central body for operator attachment
cylinder
lower flange
drive shaft
side mounting bracket
backplate
bleed screw
596 MPS control unit
THE 595 I/S AUTOMATION SYSTEM
15
2
1
14
13
Fig. 16
Table 1 Technical specifications of 595 I operator
Power supply
Absorbed power (W)
Duty cycle %
Oil type
Oil quantity (l)
Motor winding thermal
cutout
Anti-crushing system
Temperature range
Housing protection
Weight (kg)
Pump flow rate (l/min.)
Angular velocity (rpm)
Max. door weight
2
(kg/m
)
Max torque (Nm)
Max. door height (m)
Max. door weight (m)
Technical characteristics of electric motor
Speed (rpm)
Power (W)
Current drawn (A)
Power supply
1.1.
MAXIMUM DUTY CYCLE CURVE
The curve allows the maximum working time (T) to be
obtained as a function of duty cycle (F).
For example, the 595 I/S operators can operate
uninterruptedly at a duty cycle of 50%.
To ensure good operation, keep to the field of operation
lying below the curve.
Important: The curve refers to a temperature of 24°C.
Exposure to direct sunlight can result in a reduction in duty
cycle to as low as 20%.
Calculating duty cycle
The duty cycle is the percentage of effective working time
(opening + closing) with respect to the total cycle time
(opening + closing + pause times).
It is calculated using the following formula:
%F =
Ta + Tc + Tp + Ti
where:
Ta = opening time
Tc = closing time
Tp = pause time
Ti
= interval between
one complete
cycle and the
next.
14
~
230V
(+6 -10 %) 50Hz
220
50
FAAC XD 220
1
120° C
bypass valve fitted as std.
-20 ÷ +55 °C
IP 54
10
0.75
1.54
15
400
2.70
with 1 operator
3.5
with 1 operator
1400
200
1.2
~
230V
(+6 -10 %) 50Hz
Ta + Tc
X 100
Percentuale
% Duty cycle
% Fréquence
di lav. %
d'utilisation
100
90
80
70
60
50
40
30
20
10
0
1
2
3
4
5
6
7
Tempo (h)
Time (h)
Temps (h)
% Benutzungs-
% Frecuencia
frequenz
de utilización
8
9
10 11 12
10
Zeit (Std.)
Tiempo (h)

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

593

Tabla de contenido