3 - N.C. - STOP contact: any device (e.g. pushbutton)
which can stop the movement of the door by
opening an N.C. contact.
To install more than one stop device connect the
N.C. contacts in series.
N.B.: If STOP devices are not connected, jumper
terminals 3 and 4.
4 - Common signals and accessories power supply
negative
5 - + Accessories power supply positive (+ 24 Vdc)
Warning: the max. accessory load is 250 mA. To
calculate absorption values, refer to table 3.
6 - Fail-safe: if enabled, the photocell transmitter power
supply positive must be connected.
7 - N.O. closure limit switch contact
8 - Limit switch contact common
9 - N.O. opening limit switch contact
N.B.: If limit switches are not connected, do not
jumper.
J2 Terminal block (fig. 19)
10 - 11 - Starter capacitor connection
12 - 13 - 14 - Connecting electric motor
N.B.: in the case of double motor application,
connect the second motor in parallel to the one
already connected up.
15 - 16 - Timed courtesy light (230 Vac max. 40 W)
J9 Terminal block: (fig. 19)
:
Earth connection
N. :
power supply 230 V~ ( Neutre )
L.
:
power supply 230 V~ ( Phase)
N.B.: For correct operation the card must be
connected to the system's earth. Install a suitable
differential magneto-thermal circuit-breaker
upstream of the system.
Programming microswitches
Fuse F1 5x20 5 A/250 V rapid (motor power supply)
Fuse F2 5x20 800 mA/250 V delayed (accessories power
supply)
J4 quick connector for decoder SL/DS - MINIDEC SL/DS
- RP SL/DS cards (figs. 21-22-23-24).
5.2.
PROGRAMMING THE MICROSWITCHES
To program operation of the automation, set the dip-
switches as shown in Table 4.
5.2.1. OPERATION LOGICS
The following two logics are available:
A: "AUTOMATIC"
E: "SEMI-AUTOMATIC"
The operation of the logics is shown in tables 5a and 5b.
Table 3 - Current drawn by accessories
ACCESSORY
R 31
PLUS E RECEIVER
MINIDEC SL / DS
DECODER SL / DS
RP SL / DS RECEIVER
DIGICARD
METAL DIGIKEY
FOTOSWITCH
DETECTOR F4 / PS6
MINIBEAM
5.2.2. SAFETIES ON CLOSING
This function serves to select the operating mode for the
closing safeties:
- OFF: garage door stops closing and immediately starts to
open;
- ON: garage door stops closing and starts opening when
safety released.
PLUS E
596 MPS
MINIDEC
SL/DS
PLUS E
596 MPS
N.B. Use a dedicated decoder for each accessory type.
596 MPS
17
CURRENT DRAWN
50 mA
20 mA
6 mA
20 mA / 55 mA
12 mA / 6 mA
15 mA
15 mA
90 mA
50 mA
70 mA
PLUS E
596 MPS
Fig. 21
RP DS
RP SL
ENGLISH