Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
LOGIC
A
E
FSW
opens on disengagement
opens immediately
Table 5/a
LOGICS "A"
DOOR STATE
CLOSED
OPEN on PAUSE
CLOSING
OPENING
STOPPED
Table 5/b
LOGICS "E"
DOOR STATE
CLOSED
OPEN on PAUSE
CLOSING
OPENING
STOPPED
6. START-UP
Program electronic control unit 596 MPS according to your
requirements as shown in table 4.
6.1.

DIRECTION OF ROTATION

1) Switch off the power.
2) Move the door manually to the halfway position.
3) Lock the operator.
4) Switch on the power.
5) Send an OPEN pulse to the input (fig. 20) and check
that this makes the door open.
If the gate closes, invert the motor wires on the control unit
(brown and black wires).
SW1
ON
OFF
ON
OFF
SW2
ON
OFF
OPEN
Opens the door and recloses after pause time
Recloses the door immediately
Reopens the door immediately
No effect
Closes the door
OPEN
Opens the door and recloses after pause time
Recloses the door immediately
Reopens the door immediately
Recloses the door immediately
Closes the door
1 2 3 4 5 6
OPEN/CLOSE TIMES
SW3
25"
ON
30"
OFF
35"
ON
40"
OFF
PULSES
STOP
No effect (OPEN inhibited)
Stops
No effect (OPEN inhibited)
PULSES
STOP
No effect (OPEN inhibited)
Stops
No effect (OPEN inhibited)
6.2.
OPERATING TIME SELECTION
Select an operating time a few seconds longer than the
one previously timed on the electronic control unit 596 MPS
in order to obtain maximum efficiency of the hydraulic
lock.
6.3.
SELECTING PAUSE TIME
By selecting logic A it is possible to regulate the garage
door pause time by way of the relevant dip-switch.
6.4.
SELECTING FAIL-SAFE
The 596 MPS card also has a FAIL-SAFE safety device which
serves to verify that the N.C. contact on the photocell
receiver is working correctly before each operation; this
device can be disabled.
18
FAIL SAFE
YES
NO
PAUSE TIME
60"
30"
SW4
ON
ON
OFF
OFF
SAFETIES
No effect
Freezes pause until disengagement (OPEN inhibited)
See paragraph 5.2.2
No effect
No effect (OPEN inhibited)
SAFETIES
No effect
Freezes pause until disengagement (OPEN inhibited)
See paragraph 5.2.2
No effect
No effect (OPEN inhibited)
SW6
ON
OFF
SW5
ON
OFF
Table 4

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

593

Tabla de contenido