2.3.3
POWER SUPPLY CABLE
The unit is delivered fitted for one of the following voltages:
3N AC 380...415 V; 2N AC 380...415 V; 3 AC 220...240 V; 1N AC 220...240 V 50/60 Hz.
The specifications of the power supply connection flexible cable must match or be superior to those of the cable with rubber
insulation H07RN-F. Introduce the cable through the cable clamp and secure it firmly. During operation, the power supply
voltage should not differ from the voltage rating by ± 10%. The unit is supplied with a cable with the specifications given n
Tab. 3; to access the terminal block or replace it, you need to:
- remove the terminal-block box on the back of the unit
- connect the supply cable to the terminal block according to need, following the instructions given on the label located near
the terminal block and in this handbook.
MODEL
SUPPLY VOLTAGE TYPE
3N AC 380...415 V 50/60 Hz
2N AC 380...415 V 50/60 Hz
3 AC 220...240 V 50/60 Hz
1N AC 220...240 V 50/60 Hz
2.3.4
CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES
3N AC 380...415 V 50/60 Hz
2N AC 380...415 V 50/60 Hz
3 AC 220...240 V 50/60 Hz
1N AC 220...240 V 50/60 Hz
E4F6
Max.
Nb. cables
A/f
17,1
5 x 2,5
34,2
4 x 6
24
4 x 2,5
44,6
3 x 10
- 15 -
E6FA6
Max.
Nb. cables
A/f
27,5
5 x 4
34,2
4 x 6
39
4 x 6
61,7
3 x 10
P E
(Earth)
yellow-green
N
(NP)
blue
L
(T)
black
3
L
(S)
black
2
L
(R)
brown
1
P E
(Earth)
yellow-green
N
(NP)
blue
L
(S)
black
2
L
(R)
brown
1
P E
(Earth)
yellow-green
N
(NP)
blue
L
(T)
black
3
L
(R)
brown
1
P E
(Earth)
yellow-green
N
(NP)
blue
L
(R)
brown
1
E6F6
Max.
Nb. cables
A/f
27,5
5 x 4
34,2
4 x 6
39
4 x 6
61,7
3 x 10
Tab. 4
Tab. 3