Installation must be performed by qualified persons in accordance with current regulations.
WARNINGS:
If the unit is installed against a wall, the wall needs to withstand temperatures of 100°C and must be fireproof; if not, it is
essential to install thermal insulation. Before proceeding with the installation, remove the protective plastic film and elimi-
nate any adhesive residues by means of a suitable product for cleaning stainless steel. Install the oven horizontally, correct
positioning is obtained by turning the levelling feet. The various units may be installed separately or combined with other
units in the MINIMA range. This unit is not suitable for encasing.
2.1

MINIMA SERIES ELECTRIC COOKER PLATE

The technical data plate is on the back of the unit.
2.2

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES

The following regulations must be observed during installation:
- Current accident and fire regulations.
- The regulations of the electric power supply company.
- Health regulations.
- Electrical systems standards.
2.3

ELECTRICAL CONNECTION

The electrical connection must be made in compliance with CEI standards, only by authorized and skilled personnel.
Firstly, check the data given in the technical data table of this manual, on the data plate and in the wiring
diagram. The envisaged connection is of the fixed type.
IMPORTANT: A multi-polar mains cut-off device must be provided upstream from each unit,
with a contact gap of at least 3 mm., for example:
- a manual switch of suitable capacity, equipped with fuses
- circuit breaker with relevant miniature circuit breakers.
2.3.1

EARTHING

It is vital to earth the unit. Connect the terminals marked by the symbols (
an efficient grounding complying with the regulations in force.
The manufacturer cannot be considered responsible for any damage caused by failure to earth the system.
CAUTION: NEVER CUT THE GROUNDING CABLE (yellow-green)
2.3.2

EQUIPOTENTIAL SYSTEM

The unit must be included in an equipotential system whose efficiency must be checked according to the standards in force.
The screw marked with the "Equipotential" label is on the back.