 Draining the Water to Prevent Freezing
Use the following procedure to drain the water and disconnect the power if the following circumstances
are applicable.
®
● The SpaLet
seat will not be used for an extended period of time due to travel. Long-term disuse may
cause water to become contaminated. This contaminant could deposit on the toilet.
®
● The SpaLet
seat will not be used for an extended period of time due to being in a vacation home.
As temperatures drop in unoccupied houses during the course of seasons, water could freeze during
times of cold temperatures.
(1) Turn the water shutoff valve clockwise to shut off the
water supply to the tank.
(For draining in cold areas, operate the indoor drain plug.)
(2) Press the flush lever on the tank to drain water from the tank.
(3) Remove the power plug from the outlet.
(4) Drain the water from the water supply side.
(5) Push the lock lever on the right side of the seat unit and slide the
seat unit forward to remove it from the toilet bowl.
(6) Remove the strainer located on the left side of the seat unit. Place
a wash bowl or similar item underneath the strainer.
(7) Tilt the seat unit to the left to drain the water from the water
supply hose through the strainer hole.
(8) After the water has been drained, firmly attach the strainer.
(9) Place the seat unit on the toilet bowl. Slide the seat unit
backward to secure the seat unit.
(10) Check for leaks from the water shutoff valve.
27 - EN -
Lock Lever
Strainer
CAUTION
When removing the strainer, be
sure to close the water shutoff
valve. When attaching the strain-
er, fi rmly tighten it until the end of
the strainer is hidden in the seat
unit.
* Water can leak from the strainer.
End