EZLOGIC® ZONE
CONTROLLER
(MÓDULO DE
ZONA EZLOGIC
• EZDrive™ Zone Starter Box
Each zone of the model CREzd is equipped with an Ezdrive
The zone starter box provides an interface between the EzLogic
and the gearmotor. The zone starter box performs the following functions:
1. Provides power to the gearmotor
2. Allows the gearmotor to be "remotely controlled" by an EzLogic
controller.
3. Provides overload protection for the gearmotor.
4. Provides LEd's to indicate when the zone starter box is receiving power and
when the overload has tripped.
The parts of the Ezdrive™ zone starter box are shown in (Figure 7B). Each of
these parts and their function is described below.
POWER CABLE
This cable provides power to the zone starter box and gearmotor. It is terminated
with a male quick disconnect connector. The cable is connected to either the
previous zone starter box in the chain or to the disconnect panel.
POWER CONNECTOR
This connector is a female quick disconnect mounted directly to the zone starter
box. It is used to provide power to the next zone starter box in the chain. The
male connector on the power cable of the next zone starter box is plugged into this
connector. This connector is capped on the last zone starter box in the chain.
MOTOR CABLE
This cable provides the connection between the zone starter box and the motor.
The cable is hard-wired to the motor's wiring box.
RUN-ENABLE INPUT CABLE
This cable accepts a drive/no drive signal from the EzLogic® zone controller.
The cable is terminated with a male pico connector that mates with the female
connector on the solenoid output cable of the EzLogic® zone controller which
controls the gearmotor.

• Loading Applications

1
END LOADING FROM ANOTHER CONVEYOR
EZLOGIC® ZONE CONTROLLER (DIFFUSE SHOWN)
(módUlO de zOna ezlOgIC
INFEED ZONE
(zOna de alImentaCIOn)
INFEED
CONVEYOR
(transpOrtadOr
alImentadOr)
WAKE-UP EYE
CONTROLS REQUIREd:
If the infeed zone is occupied, some method is needed to control the infeed
conveyor (if powered). A photo cell may be placed in infeed zone to signal
that zone is occupied or an EzLogic® I/O auxiliary module may be con-
nected to the zone controller in the infeed zone to provide signal that infeed
zone is occupied. A wake-up eye senses an incoming load and wakes the
zone up.
EZLOGIC® ZONE CONTROLLER (DIFFUSE SHOWN)
(módUlO de zOna ezlOgIC
CRR
EXTENSION CABLE
®
)
(CABLE DE EXTENSIÓN)
zone starter box.
zone controller
®
) [dIFUsO mOstradO]
®
FLOW
(FlUJO)
) [dIFUsO mOstradO]
®
INFEED ZONE
(zOna de alImentaCIOn)
FLOW
(FlUJO)
ZONE CONTROLLER CORDSET
(CABLEADO DEL MÓDULO DE ZONA)
Power Indicator LED (Green)
This LEd will be illuminated at all times if power is connected to the zone starter
box.
OVERLOAD INDICATOR LED (RED)
zone
®
This LEd will be illuminated if the zone starter box's motor overload is tripped. The
zone starter box must be manually reset when this indicator is lit.
OVERLOAD RESET BUTTON
This button is used to reset the motor overload if it is tripped. If the red LEd is
illuminated, press this button to reset the overload.
CAUTION! Before resetting the zone starter box overload, check the con-
veyor zone to be sure that it is free of obstruction or is not jammed or "bound
up" in any way. depending on load positions or whether or not an Ezlogic®
zone controller has been "flagged," the zone mAY START UP ImmEdIATELY
WHEN THE RESET BUTTON IS PRESSEd!
FIGURE 7B
POWER CABLE
POWER INDICATOR
LED (GREEN)
MOTOR CABLE
2
END LOADING FROM TURNTABLE
EZLOGIC® ZONE CONTROLLER (DIFFUSE SHOWN)
EZLOGIC® ZONE CONTROLLER (DIFFUSE SHOWN)
(módUlO de zOna ezlOgIC
TRACKS
(rIeles)
7
FIGURE 7A
ZONE STARTER BOX
(mOtOr COntrOladOr)
OVERLOAD RESET
BUTTON (BLUE)
(módUlO de zOna ezlOgIC
) [dIFUsO mOstradO]
®
INFEED ZONE
(zOna de alImentaCIOn)
FLOW
(FlUJO)
TURNTABLE/CRR MOUNTED
(mesa gIratOrIa/Crr mOntadO)
CONTROLS REQUIREd:
Same as Item #1.
) [dIFUsO mOstradO]
®
INFEED ZONE
(zOna de alImentaCIOn)
FLOW
(FlUJO)
POWER
CONNECTOR
OVERLOAD
INDICATOR
LED (RED)
RUN ENABLE
INPUT CABLE

Publicidad