INSTALLATION

• Support Installation

1. determine direction of prod-
uct flow. Figure 4A indicates the
flow as related to the EzLogic ®
controls.
2. Refer to "match-mark" num-
bers on ends of conveyor sec-
tions. (Figure 4A.) Position them
in this sequence near area of
installation.
3. Attach supports to all convey-
or sections as shown in Figures
4B and 4C. Hand tighten bolts
only at this time.
4. Adjust elevation to required
height.
FIGURE 4B

• Conveyor Set-Up

1. mark a chalk line on floor to locate center of the conveyor.
2. Place the infeed section in position.
3. Place remaining sections on extended support of previous section.
4. Fasten sections together with butt couplings and pivot plates (Figure 4C). Hand tighten
bolts only at this time.
5. Check to see that conveyor is level across width and length of unit. Adjust supports as
necessary.
6. Tighten all butt couplings and support mounting bolts and lag conveyor to floor.
7. Connect EzLogic® cordset and Ezdrive™ cable (Fig. 5A).
8. Install electrical controls and wire disconnect panel (Figure 4d). The dual Output
disconnect Panel requires a 30 amp service and the Single Output disconnect Panel
requires a 15 amp service. All lines must have
proper Fuse or Breakers.
See disconnect
Panel for required voltage.
9. Connect IOP to EzLogic®. See EzLogic®
GEN3 Component manual for more information
about IOP.
Note! All drive roller shafts are turned to within
10 thousandths TIR (Total Indicator Runout).
Some wobbling of the gearmotor may be notice-
able and is typical in Torque Arm mounted
gearmotors. This allows the gearmotor to float
which prevents fatiguing of the drive shaft or
premature failure of bearing components.
FIGURE 4A
INFEEd zONE
(zOna de alImentaCIOn)
FLOW
KNEE BRACE ANGLE
(angUlO de sOpOrte)
INTERMEDIATE
SUPPORTS
(sOpOrtes
IntermedIOs)
FIGURE 4D
SINGLE OUTPUT DISCONNECT
NOTE: CUSTOMER MUST SUPPLY 15 AMP OR 30 AMP OVERCURRENT PROTECTION TO ALL DISCONNECT PANELS.
INTERmEdIATE zONE
(zOna IntermedIa)
EzLOGIC®
zONE CONTROLLER
(dIFFUSE SHOWN)
(COntrOladOr de zOna ezlOgIC®)
[dIFUsO es mOstradO]
SUPPORTS
(sOpOrtes)
FIGURE 4C
MOUNTING BOLT
(tOrnIllO de mOntaJe)
SIDE CHANNEL
(Canal lateral)
L1
(l1)
L2
(l2)
L3
(l3)
GROUND
(COneXIOn a tIerra)
PANEL - 15 AMP
4
dISCHARGE zONE
(zOna de desCarga)
P-1
P-1
mARK_______________________
mARK_______________________
"mATCH-mARK" NUmBERS
00001
00001
CONVEYOR F.O.#_____________
CONVEYOR F.O.#_____________
(etIQUetas de seCUenCIa de armadO)
1
2
2
1
ITEm___________ T O___________
ITEm___________ T O___________
HYTROL CONVEYOR CO. INC.
HYTROL CONVEYOR CO. INC.
JONESBORO, AR
JONESBORO, AR
SUPPORT
(sOpOrte)
BUTT COUPLINGS
(plaCas de empalme)
15A BREAKER
(dIsYUntOr de 15a)
DUAL OUTPUT DISCONNECT
PANEL - 30 AMP
ADJUST TO DESIRED
ELEVATION
(aJUste a la altUra
deseada)
SIDE CHANNELS
(Canal lateral)
PIVOT PLATE
(plaCa pIVOte)
STATIONARY SUPPORT
(sOpOrte estaCIOnarIO)
L1
(l1)
L2
(l2)
L3
(l3)
GROUND
(COneXIOn a tIerra)