• Racked Sections

It is important that each bed section be checked for an out-of-square con-
dition. If conveyor is not square, tracking problems will result. Figure 5B
indicates a racked section.
TO CORRECT AN OUT-OF-SQUARE SECTION
1. Locate points on corners of section and measure distance "A" & "B". If the
dimensions are not equal, the section will need to be squared. (Figure 5B).
2. After all bed sections have been checked and corrected for "racked condi-
tion", tighten all butt couplings and pivot plate bolts.
3. make final check to see that all conveyor sections are level across width
and length. If entire conveyor is level, supports can be lagged to floor.
"Racked" conveyor sections will cause product to travel toward side of con-
veyor.
IMPORTANT! Being out of level across this width of conveyor
can cause product drift on long conveyor lines.

• Electrical Equipment

WARNING! Electrical controls shall be installed and wired by a qualified electri-
cian. Wiring information for the motor and controls are furnished by the equip-
ment manufacturer.
CONTROLS
Electrical Code: All motor controls and wiring shall conform to the National
Electrical Code (Article 670 or other applicable articles) as published by the
National Fire Protection Association and as approved by the American Standards
Institute, Inc.
CONTROL STATIONS
A) Control stations should be so arranged and located that the operation of the
equipment is visible from them, and shall be clearly marked or labeled to indicate
the function controlled.
B)
A conveyor which would cause injury when started shall not be started until
employees in the area are alerted by a signal or by a designated person that the
conveyor is about to start.
When a conveyor would cause injury when started and is automatically
controlled or must be controlled from a remote location, an audible device shall
EZLOGIC® ZONE CONTROLLER
(módUlO de zOna ezlOgIC®)
ZONE GEARMOTOR
IOP
(mOtOr en zOna)
FLOW
EZLOGIC® ZONE CONTROLLER
(módUlO de zOna ezlOgIC®)
dISCONNECT PANEL
(PANEL dE CONTROL)
SINGLE OUTPUT
(PANEL dE SALIdA SENCILLO)
dUAL OUTPUT
(PANEL dE SALIdA dOBLE)
ELECTRICAL END CAP
(tapOn de UltIma
COneXIOn eleCtrICa)
EZDRIVE™ ZONE STARTER BOX
(COntrOladOr de zOna ezdrIVe™)
IOP
(IOp)
ZONE GEARMOTOR
(mOtOr en zOna)
DUAL OUTPUT DISCONNECT PANEL
(mUST BE LOCATEd AT THE CENTER OF CONVEYOR)
PANEL DE SALIDA DOBLE CON FUENTE DE PODER
(debe ser UbICada en el CentrO del transpOrtadOr)
50 FT. MAXIMUM DISTANCE
(SEE CHART FOR NUmBER OF zONES)
50 FT. DISTANCIA MÁXIMA
(Ver CUadrO para el nÚmerO de zOnas)
FIGURE 5B
A1
SIDE CHANNEL
(CANAL LATERAL)
ROLLERS NOT
SQUARE WITH
SIDE CHANNELS
(RODILLOS
DESCUADRADOS
CON CANALES
LATERALES)
A2
be provided which can be clearly heard at all points along the conveyor where
personnel may be present. The warning device shall be actuated by the controller
device starting the conveyor and shall continue for a required period of time
before the conveyor starts. A flashing light or similar visual warning may be used
in conjunction with or in place of the audible device if more effective in particular
circumstances.
Where system function would be seriously hindered or adversely affected by
the required time delay or where the intent of the warning may be misinterpreted
(i.e., a work area with many different conveyors and allied devices), clear, concise,
and legible warning shall be provided. The warning shall indicate that conveyors
and allied equipment may be started at any time, that danger exists, and that
personnel must keep clear. The warnings shall be provided along the conveyor at
areas not guarded by position or location.
C) Remotely and automatically controlled conveyors, and conveyors where
operator stations are not manned or are beyond voice and visual contact from drive
areas, loading areas, transfer points, and other potentially hazardous locations on
the conveyor path not guarded by location, position, or guards, shall be furnished
with emergency stop buttons, pull cords, limit switches, or similar emergency stop
devices.
All such emergency stop devices shall be easily identifiable in the immediate
vicinity of such locations unless guarded by location, position, or guards. Where
the design, function, and operation of such conveyor clearly is not hazardous to
5
208/230V
460V
3 PH. 60 Hz
3 PH. 60 Hz
1-5 zONES
1-10 zONES
(1-5 zONAS)
(1-10 zONAS)
6-10 zONES