Wiring The Brakes And Microswitches; Wiring The Motor With «External Connection Box» Option; Encoder Wiring - Leroy-Somer GEARLESS XAF1 Manual Del Usaurio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LEROY-SOMER
Permanent magnet synchronous motor for lifts
This table is given for information only, and must
under no circumstances be used in place of the current
standards.
The recommended cross-sections are given for a
singlewire cable, with a maximum length of 10 m. Above
this, line drops due to the cable length must be taken
into account.
Particular care must be taken when tightening the nuts on the
terminals. (incorrect tightening may lead to the connections
being damaged by overheating)
- connect the power cables to terminals U1, V1 and W1, in
accordance with iec 600034-1.
- connect the thermal probe (option) to the drive.
- connect the motor ground (green/yellow wire) to earth.
- connect the shield of the power cable.
- connect the shield of the thermal probe (option).

4.2.2 - Wiring the brakes and microswitches

the brake microswitches are of «nc» type.
When using an optional cDF6 power supply, please refer to
the card manual.
the supply of the brake must be done on the 6 pin connector
WaGo 260-106 located on the back of the brake (except
terminal box option):
N° of Pin
1
2
Blue Wire : Common Coil A and B
3
4
Black Wire : Micro-contact A
Grey Wire : Common Micro-contact
5
6
Black Wire : Micro-contact B
Electrical connection of the brake:
Brake inductor voltage and current values indicated on the
nameplate are given for each brake coil.
22
installation anD maintenance
MICRO GEARLESS XAF1
Connexion
Black Wire : Coil A
Black Wire : Coil B
A et B
example: Holding Voltage: 103VDc / current: 0.57a
205 V
103 V
0,57 a - 103 V
Dc
4.2.3 - Wiring the motor with «external
connection box»
a terminal connection diagram is included in the in the cover
of the terminal box.

4.2.4 - Encoder wiring

never touch the pins of the encoder connector. Risk of
destruction by electro-static discharge!
- identify the encoder by means of the reference indicated on
the encoder label (Fig. 7)
- connect the encoder to the drive by means of the sUB-D15
socket.
ECN 413 encoder: sincos encoder with enDat link.
ERN 426 encoder: Incremental encoder
4784 - 2013.02 / b