HDO 125
i
n
[min
HDO 125 2
7.4
243
HDO 125 2
8.0
226
HDO 125 2
8.8
204
HDO 125 2
9.9
182
HDO 125 2
11.5
157
HDO 125 2
12.3
146
HDO 125 2
14.2
127
HDO 125 2
15.3
118
HDO 125 2
16.9
106
HDO 125 3
19.2
94
HDO 125 3
22.6
80
HDO 125 3
24.3
74
HDO 125 3
27.7
65
HDO 125 3
33.0
54
HDO 125 3
35.8
50
HDO 125 3
38.8
46
HDO 125 3
43.0
42
HDO 125 3
50.1
36
HDO 125 3
55.4
32
HDO 125 3
60.1
29.9
HDO 125 3
72.1
25.0
HDO 125 3
77.6
23.2
HDO 125 3
85.9
20.9
HDO 125 4
97.0
18.6
HDO 125 4
116.3
15.5
HDO 125 4
125.2
14.4
HDO 125 4
141.8
12.7
HDO 125 4
152.6
11.8
HDO 125 4
178.0
10.1
HDO 125 4
200.3
9.0
HDO 125 4
226.9
7.9
HDO 125 4
244.1
7.4
HDO 125 4
284.8
6.3
HDO 125 4
315.2
5.7
HDO 125 4
367.6
4.9
HDO 125 4
395.6
4.5
HDO 125 4
438.0
4.1
*
Mn
Pn
2
2
1
-1
]
[Nm]
[kW]
[kW]
29330
777
31560
777
34940
776
36250
720
35910
614
37300
593
34960
482
36350
466
38880
450
190
33640
350
35190
312
144
37860
312
148
38150
275
155
41240
250
159
41760
234
159
43250
223
160
44620
208
160
46050
184
163
46570
168
163
42420
141
—
47620
132
—
49240
127
—
46160
108
—
37170
78
—
44590
78
—
47980
78
—
42600
61
—
45850
61
—
46190
53
—
42070
43
—
47230
43
—
48720
41
—
47230
34
—
49240
32
—
47750
27
—
49240
25
—
49240
23
—
Comprobación térmica no necesaria
—
Tamb = 20°C
[kW]
[kW]
[kW]
*
330
336
414
*
334
340
418
*
338
344
422
*
339
345
423
*
353
359
437
*
356
362
440
*
342
348
426
*
343
349
427
359
365
443
*
254
265
322
260
271
328
264
275
332
271
282
275
286
275
286
276
287
276
287
279
290
279
290
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
n
= 1800 min
1
[kW]
[kW]
*
*
*
*
*
*
*
*
272
300
275
303
261
289
262
290
278
306
201
222
207
228
211
232
—
218
239
—
222
243
—
222
243
—
223
244
—
223
244
—
226
247
—
226
247
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
231 / 306
-1
[kW]
371
375
379
380
394
397
383
384
400
290
296
300
307
311
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—