HDO 125
i
n
[min
HDO 125 2
7.4
162
HDO 125 2
8.0
150
HDO 125 2
8.8
136
HDO 125 2
9.9
122
HDO 125 2
11.5
105
HDO 125 2
12.3
97
HDO 125 2
14.2
84
HDO 125 2
15.3
78
HDO 125 2
16.9
71
HDO 125 3
19.2
62
HDO 125 3
22.6
53
HDO 125 3
24.3
49
HDO 125 3
27.7
43
HDO 125 3
33.0
36
HDO 125 3
35.8
34
HDO 125 3
38.8
31
HDO 125 3
43.0
27.9
HDO 125 3
50.1
24.0
HDO 125 3
55.4
21.6
HDO 125 3
60.1
20.0
HDO 125 3
72.1
16.6
HDO 125 3
77.6
15.5
HDO 125 3
85.9
14.0
HDO 125 4
97.0
12.4
HDO 125 4
116.3
10.3
HDO 125 4
125.2
9.6
HDO 125 4
141.8
8.5
HDO 125 4
152.6
7.9
HDO 125 4
178.0
6.7
HDO 125 4
200.3
6.0
HDO 125 4
226.9
5.3
HDO 125 4
244.1
4.9
HDO 125 4
284.8
4.2
HDO 125 4
315.2
3.8
HDO 125 4
367.6
3.3
HDO 125 4
395.6
3.0
HDO 125 4
438.0
2.7
*
Mn
Pn
2
2
1
-1
]
[Nm]
[kW]
[kW]
33130
585
35650
585
39430
584
38520
510
35910
410
206
37300
395
208
34970
322
199
36350
311
200
38880
300
210
36480
253
156
39740
235
159
42760
235
162
43090
207
166
46570
188
168
47160
176
168
46270
159
—
46420
144
—
49240
131
—
46190
111
—
47910
106
—
47750
88
—
49240
85
—
46530
72
—
41970
59
—
47750
56
—
49240
54
—
47230
45
—
48720
43
—
47230
36
—
47510
32
—
47230
28
—
48720
27
—
47230
23
—
49240
21
—
47750
17.7
—
49240
17.0
—
49240
15.3
—
Comprobación térmica no necesaria
—
Tamb = 20°C
[kW]
[kW]
[kW]
*
324
367
445
*
327
370
448
*
329
372
450
*
330
373
451
338
381
459
340
383
461
331
374
332
375
342
385
247
283
250
286
253
289
257
293
259
295
259
295
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
n
= 1200 min
1
[kW]
[kW]
280
308
283
311
285
313
286
314
294
322
296
324
—
287
315
—
288
316
—
298
326
—
219
240
—
222
243
—
225
246
—
229
250
—
231
252
—
231
252
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
235 / 306
-1
[kW]
402
405
407
408
416
418
409
—
—
308
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—