1. INSTALL DUCTWORK
Plan where and how the ductwork will be installed. Install proper-sized ductwork, elbows and roof or wall cap for the type
of blower you are installing. Use 2" duct tape to seal duct joints.
NOTE: When performing vertical exhaust ductwork, there must be at least 14" high free inside cabinet in order to
allow cabinet blower installation.
The minimum hood distance above cooktop must not be less than 24". A maximum of 30" above cooktop is
highly recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
Roof cap
Wall
cap
HH0045A
2. PREPARE THE INSTALLATION
Make sure that the following items are included:
- Hood
- Accessories:
• Filters (2 for 30'' and 36'' width hoods, 3 for 42'' width hood)
• Cabinet blower including left and right flow deviators (assembled to cabinet blower)
• Electrical cable with 3-prong redeptacle (inside one filler)
• 3¼" x 14" adapter/damper (inside one filler)
• Bag of parts (inside one filler) including:
(2) wire clamps, (5) no. 8 x 1/2" screws, (3) wire connectors, (9) no. 8 x 3/8" screws
Parts sold separately:
- Halogen lights (MR16, GU10, 120 V, 50 W)
- Transition 3¼" x 14" to 8" round model no. 459 (optional), transition 3¼" x 14" to 7" round model no. T460 (optional),
adaptor/damper 3¼" x 14" to 3¼" x 10" model T461 (optional), ducts, elbows, dampers, wall and roof caps. Refer to
page 1 for a complete list of venting options and model numbers.
NOTES: 1. During installation, protect countertop and/or cooktop.
2. If the bottom of the cabinet is recessed, attach three 1'' width wood strip (not included). Refer to figure below
for wood strips proper location.
3¼" x 14" duct
OR 3¼" x 10"
3¼" x 14" to
3¼" x 10" adaptor
model T461 (optional)
Cabinet blower
Hood
24" minimum above
cooking surface
CABINET BOTTOM
1"
1"
1
¾
' '
HO0045A
Roof cap
Wall
cap
HH0046A
1"
10¼''
1
¾
' '
- 2 -
7" OR 8" round duct
Transition model 459
3¼" x 14" to 8" OR
model T460
3¼" x 14" to 7"
Cabinet blower
Hood
24" minimum above
cooking surface