Frost Precautions - Zanussi ZWI 71000 WA Manual De Instrucciones

Ocultar thumbs Ver también para ZWI 71000 WA:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

45°
20°

FROST PRECAUTIONS

If the appliance is installed in an area where the
temperature can be less than 0° C, remove the
remaining water from the inlet hose and the drain
pump.
1. Disconnect the mains plug from the mains
socket.
2. Close the water tap.
3. Place the end of the emergency emptying hose
and that of the inlet hose in a bowl placed on
the floor and let water flow out of the hoses.
4. Set the Drain programme and let it operate until
the end of the cycle.
5. Turn the programme knob to
the appliance from the power supply.
6. Screw the water inlet hose back on and re-fit
the emergency emptying hose after having put
the cap on again.
TROUBLESHOOTING
WARNING! Refer to Safety chapters.
INTRODUCTION
The start of the appliance does not occur or it
stops during operation.
First try to find a solution to the problem (refer to
the table). If not, contact the Authorised Service
Centre.
With some problems, the acoustic signals operate.
The red indicator of the button Inicio/Pausa flashes
and one of the phase indicators comes on, to show
an alarm code:
Screw the hose back
to the machine and
make sure the
connection is tight.
Turn on the water tap.
to disconnect
WARNING! Make sure that the
temperature is more than 0 °C before
you use the appliance again.
The manufacturer is not responsible
for damages caused by low
temperatures.
FROST PRECAUTIONS
If the appliance does not drain the water, proceed
as follows:
1. Disconnect the mains plug from the mains
socket.
2. Close the water tap.
3. if necessary, wait until the water has cooled
down.
4. Place a bowl on the floor and put the end of
the emergency emptying hose into the bowl.
Remove its cap.
The water should drain by gravity into the bowl.
5. When the bowl is full, put the cap back on the
emergency hose.
6. Empty the bowl. Repeat the procedure until
water stops flowing out.
7. Clean the pump if necessary as previously
described.
8. Replace the emergency emptying hose in its
seat after having plugged it.
9. Screw the water inlet hose back on.
Prelava./Lava. - The appliance does not fill with
water properly.
Aclarados/Enxag. Centrifugar - The appliance
does not drain the water.
Fin/Fim - The appliance door is open or not
closed correctly. Please check the door!
The indicator of button Inicio/Pausa flashes in
red 11 times and 1 (or 2 or 3) time(s) in green:
the mains supply is unstable. Wait until the
mains supply is stable and the appliance
automatically starts operating.
WARNING! Deactivate the appliance
before you do the checks.
15

Publicidad

Tabla de contenido
loading