TECHNICAL DATA
MODEL
Thermal power
Capacity B/P
Capacity Natural Gas
Pressure Natural Gas
Pressure B/P
Category
Weight
Motor
Condenser 450 V
Transformer
Electrical input
Total absorbed power
Flame control
Air adjustment
Number of stages
N.B. The values of fuel consumption are meant with gas at 15°C and 1013 mbar
WORKING CURVES
G35 gas
6
5,6 mbar
160 kW
5
4
3
3 mbar
115 kW
2
1
0
100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
Capacity kW
They show the capacity in Kw, according to the counterpressure in Mbar in the combustion chamber.
min.
kW
max.
kW
min.
kcal/h
max.
kcal/h
min.
m
/h
3
m
/h
max.
3
min.
m
/h
3
m
/h
max.
3
mbar
mbar
kg
W
µF
kV/mA
W
G35/2 gas
5,6 mbar
163 kW
G35/M gas
G35/2 gas
3 mbar
188 kW
G35 gas
G35 gas
G35/2 gas
188
115
320
390
161.680
98.900
275.200
335.400
7
4,3
12
14,7
19,9
12,2
33,9
41,3
20
20
30
30
II 2H3+
40
41
370
370
14
14
12/35
12/35
230V - 50 Hz Monophase
950
1000
Ionisation
Manual
Powered
1
G35/M gas
3,25 mbar
310 kW
3 mbar
300 kW
2 mbar
275 kW
0,5 mbar
320 kW
pag. 45
G35/M gas
163
390
140.180
335.400
6,1
14,7
17,2
41,3
20
30
42
370
14
12/35
1050
Powered
2
Modulating
0,25 mbar
390 kW