Festo DNCI Instrucciones De Utilizacion página 24

Ocultar thumbs Ver también para DNCI:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
DNCI
If the DNCI is used with electronic control:
Connect the measuring system connection with the cable in accordance with
S
the manuals for the positioning controller.
If the DNCI is used as a measuring cylinder:
Connect the measuring system as follows:
S
Pin
1
2
3
4
5
6
7
8
Fig. 11
6
Commissioning
Warning
Uncontrolled moving parts can cause injury
to people in the vicinity of the DNCI.
S Make sure that nobody can place his/her
hand in the positioning range of the
work load (e.g. by means of a protective
screen). If the DNCI is protected cor
rectly, it should not be possible to gain
access to it until it has come to a com
plete stand.
S Make sure that no objects project into
the positioning range of the work load.
24
Cable colour
Designation
black
+Ub
brown
0 V
red
Signal sine +
orange
Signal sine −
green
Signal cosine −
yellow
Signal cosine +
Screening/shield
Screening/earth
n.c.
Pin assignment (view of plug)
Fig. 12
Festo DNCI 0907c English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dnci 32Dnci 40Dnci 50Dnci 63

Tabla de contenido