Noise Emission; Installation; Receipt And Content Verification; Packaging - DVP LC.2 Instrucciones De Funcionamiento Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.4

NOISE EMISSION

This pump has been designed and constructed to reduce noise at its source.
The sound pressure levels contained in the table of technical specifications were measured at maximum vacuum
and outlet conveyed according to UNI EN 2151.
4

INSTALLATION

4.1

RECEIPT AND CONTENT VERIFICATION

Upon receipt of the pump, verify that the packaging is intact. If everything is intact, unpack the contents and check
the pump. If packaging shows signs of damage due to transport or storage conditions, immediately notify the
shipping agent and the manufacturer.
It is always necessary to check that the material received corresponds to its accompanying document.
Packages should be opened taking all precautions to avoid harm to people and the contents thereof.
4.2

PACKAGING

Depending on the size and based on the mode of transport, the pump is packaged in the following ways:
• single box with infill material;
• on wooden pallets with cardboard covers;
• in single boxes positioned on pallets with protective film.
The pallet wood can be reused or recycled in accordance with applicable laws in the country of pump installation.
Other materials such as cardboard, plastic or protective film must be disposed of in accordance with local
regulations.
Do not burn or disperse package components in the environment.
4.3

TRANSPORT AND HANDLING

HAZARD
All transportation, lifting and handling operation must be performed by qualified and experienced
personnel.
The pump can be lifted and moved with forklifts or with lifting equipment (ropes, hooks, etc.) that are appropriate to
the weight indicated in the table of technical data and on the identification plate. Manual handling and transportation
are permitted only in accordance with local regulations.
WARNING
Prepare the pump as detailed in the next chapter and empty the oil tank (see "Changing the oil")
for transport.
4.4

STORAGE

Drain the pump of oil inside and close the intake and outlet with the appropriate protections. The pumps are to be
stored in their packaging and stored in covered, dry, protected places that are not exposed to bright sunlight, with
temperatures in the range indicated in the table of technical specifications.
In case of long periods of stop inside the warehouse or out of production with storage, the location should meet the
specifications described in Chapter 3 (Pump description). In order to keep rubber parts and lip seals efficient and
properly working, we recommend to operate the pump for at least 30 minutes every 6 months with the intake
closed, following the instructions and provisions described in this manual, paying particular attention to those in
Chapter 5 (Use instructions). The non-observance of the provisions could cause the rubber parts to degrade leading
to oil leakages during operation.
8702036 – 12/04/2016 – R.7
Operating and Maintenance Instructions
LC.2 – LC.4 – LB.5 – LB.6 – LB.8 – LC.12 – LC.20
11
EN
www.dvp.it

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lc.4Lb.5Lb.6Lb.8Lc.12Lc.20

Tabla de contenido