NOTICE
The higher the level sensor is adjusted, the higher the
switch-on and switch-off point.
See the following table for application examples:
Min / Max
Shaft with a diame-
ter < of approx.
1 m (e.g. drainage)
Float basin, pond
(only SP 7 Flat In-
ox) or something
similar
Set the switch to automatic mode (AUTO).
Insert the mains plug into the socket.
Manual operation
NOTICE
In manual operation the pump remains switched on
continuously.
Illustration
Set the switch to manual operation (MAN).
Insert the mains plug into the socket.
ATTENTION
Risk of damage! Dry running leads to increased wear;
never leave the pump unattended during manual oper-
ation. Unplug immediately in case of dry running
12
SP 6 Flat Inox SP 7 Dirt Inox
Level sensor in
Level sensor in
the upmost po-
the upmost posi-
sition
tion
It is recom-
Pre-filter flaps
mended to use
closed (protec-
the pre-filter.
tion against soil-
ing)
Level sensor in
Level sensor in
the lowest posi-
the lowest posi-
tion
tion
Start pumping
Pre-filter flaps
operations with
closed (protec-
pre-filter or
tion against soil-
folded out sup-
ing)
port legs
Continuation
-
pumping oper-
ations without
pre-filter and
folded in sup-
port legs (resid-
ual fluid height
1 mm is
reached)
Note
Perform in
manual mode.
Check the
switch-off/shal-
low suction.
Flat vacuuming (SP 6 Flat Inox)
It is recommended to use manual mode to reach the
min. residual fluid height of 1 mm.
A check valve is installed for the SP 6 Flat Inox. This
prevents residual fluid in the hose from flowing back af-
ter the pumping process finishes.
Finish operation
NOTICE
Soiling can deposit and lead to malfunctions.
Pump clear water or thoroughly rinse the pump af-
ter every use.
This especially applies after pumping chlorinated
water or other liquids that leave residue.
Disconnect the main plug from the socket.
The pump is maintenace-free.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance during transport (see Spec-
ifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle
secure it from slipping.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance when selecting a storage lo-
cation for it (see Specifications).
Completely drain the pump and allow it to dry.
Store the pump in a frost-free place.
– 3
EN
Maintenance
Transport
Storage
Storing the pump