PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
• Caution! The installation of both anti-derailment buffers is absolutely obbligatory before starting programming
• Make sure that the LEDs "L6", "L7", "L8" are all lit and that the jumper "J3" (manual operation mode) is not inserted.
Note: If the block symbol
• Open the "Standard wiring diagram" which is folded inside the last page of this manual and carry out the programming procedure.
Caution: If the symbol
after 3 minutes has passed since the programmer
was powered up, the gate will start moving auto-
matically (after the warning lights have flashed for
10 seconds) to the completely closed position
(automatic repositioning).
D1
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE PARAMETER
DEFINITION LETTER "d" WILL APPEAR
ON THE DISPLAY (STAGE "A")
AFTER 1 SECOND THE DIGIT "1" WILL APPEAR
(FIRST PROGRAMMING STEP). THIS NUMBER CAN
BE EITHER FLASHING OR FIXED
ACTIVE
FUNCTION
Radio
PRESS
control
PROG
open - close
Note 1
PRESS SEL
Automatic
PRESS
reclosing
PROG
activated
PRESS SEL
PRESS
Preflashing
PROG
activated
PRESS SEL
Fixed
PRESS
warning light
PROG
output
PRESS SEL
Fixed
PRESS
indicator light
PROG
PRESS SEL
FTC_I
also active
PRESS
during a block
PROG
Note 3
PRESS SEL
FTC_S
test
PRESS
activated
PROG
Notes 4,6
PRESS SEL
appears on the display you cannot continue programming.
appears on the display
1...4... sec.
1... sec.
ACTIVE
FUNCTION
Radio control
open - block
close - block
Automatic
reclosing
excluded
Preflashing
excluded
Intermittent
warning light
output
Intermittent
indicator light
Note 2
FTC_I
only active
during closing
FTC_S
test
deactivated
Note 5
Importing notes regarding the programmer settings
Note 1 Travel direction inversion only during the closing stage.
Note 2 The indicator light flashes slowly during opening, quickly during
closing; remains lit when the gate/door is not completely closed
and is off when the gate is completely closed.
Note 3 If the photoelectric cells are in alarm and the gate is blocked no
movement commands will be accepted (not even in the opening
direction).
Note 4 If the safety device test has been activated you must connect both
the transmitter part as well as the receiver part to the CTRL 24Vdc
input between binding posts 4 and 3.
Note 5 The test is disactivated if the NC safety devices are bridged.
Note 6 If the security device test is activated there will be a one second
delay between the arrival of a command and its execution.
Note 7 In this mode the FTC_S input is managed in the same way as the
current sensor, it therefore the gate inverts for 10 cm, stops for 3
minutes and then continues moving after a 10 second preflashing
period has elapsed.
Attention! In this mode you may only connect a contact safety edge
to this contact.
Note 8 When the FTC_S security device is once again, after the pause
period has elapsed, the gate will move in the closing direction (only
in the automatic mode).
CURRENT SENSOR
The programmer checks the electrical input to the motor, detecting any
eventual increase in effort above the normal operating limits and intervenes
as an additional safety device.
When the sensor intervenes the gate will automatically invert for 10 cm, both
in the closing as well as the opening direction, to free the obstacle it will then
stop for 3 minutes and then continue moving in the original direction after
a 10 second preflashing period has elapsed.
FTC_I
test
PRESS
activated
Notes 4,6
PRESS SEL
Left-hand
motor
installation
PRESS SEL
Second
radio function
works as
TAL
PRESS SEL
Input FTC_S
used for
a safety edge
Note 7
PRESS SEL
PRESS
SEL
1...20 sec.
WAIT FOR ABOUT 20 SECONDS
WITHOUT PRESSING ANY BUTTONS:
THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND
WILL QUIT PROGRAMMING.
16
FTC_I
test
PROG
deactivated
Note 5
Right-hand
motor
PRESS
PROG
installation
Second
radio function
PRESS
works as
PROG
TB
Input FTC_S
used for a
PRESS
Stop photocell
PROG
Note 8
PRESS
PROG
CONTINUE ON
PAGE 17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sl15241524

Tabla de contenido