1. n
1.1 g
enerAl notes on sAfety
This operation manual is applicable for the machine LBC
16-TOP.
The machine may only be handled by personnel
who are qualified.
1.2 u
se of the mAchine for PurPoses for
which it is intended
La machine est destinée à meuler, matifier, structurer,
brosser, polir et lisser les métaux, le bois, le plastique et
autres matériaux semblables.
1.3 i
ncorrect use
All uses other than those described under section
1.2 are regarded as incorrect use and are there-
fore not admissible.
1.4 ec
declArAtion of conformity
Otto Suhner AG, Industriestrasse 10, CH-5242 Lupfig,
hereby declares under sole responsibility that the product
with the serial or batch no. (see reverse side) complies
with the requirements under the Directive 2006/42/EG.
Applied standards: EN ISO 12100, EN ISO 11148. Docu-
ment Agent: M. Voyame. CH-Lupfig, 12/2017
M. Voyame/Division manager
2. c
2.1 P
rior to tAKing the mAchine into serVice
Oiled compressed air is recommended (see also
air quality under section 2.3).
Observe national regulations. Check the grinding
belt before use. The driver roller must be installed cen-
trally and aligned to the stop. Under no circumstances
must the grinding belt exceed the max permitted speed.
Observe national regulations. Take protective measures
when dust can develop during working that is harmful to
one's health, cumbustible or explosive. Wear a dust mask
and work with dust/chip extraction when connectable.
18
S
oteS on
afety
ommISSIonIng
2.2 t
AKing the mAchine into serVice
2.2.1 t
/t
urn on
urn off
Tilt lock forward and press lever on plastic sleeve. Releas-
ing the lever switches the machine OFF.
2.3 r
Ating dAtA
Pressure
Power output
Air consumption full load
Air consumption at idling
Setting oiler idle
No-load speed
Sound pressure level EN ISO 15744 83dB(A), K=3dB(A)
Sound power level EN ISO 15744
Vibration EN ISO 28927-12
Air quality DIN ISO 8573-1
Weight
2.4 g
rinding Belt And non woVen
Belt length
Belt width
Belt thickness up to
Belt tension
Belt speed
Drive roller
2.5 o
PerAting conditions
Temperature range during operation: 0 to +40°C
Relative air humidity: 95% at +10°C not condensed
max. 6.3bar
330W
3
0.65m
/min
3
0.79m
/min
3-4 drops/min
-1
18'000min
94dB(A), K=3dB(A)
2
2
0.91m/s
, K=0.59m/s
3/4/4
1.230kg
520mm / 20 1/2"
3-19mm / 1/8"-3/4"
4mm
40-90N
28m/s
Ø30mm