Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure displacement water heaters is
not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Supply voltage:
6 V-Lithium battery (Type CR-P2)
• Automatic safety stop (factory setting):
• Tails time (factory setting):
• Reception range with to Kodak Gray Card, grey page,
8 x 10", landscape (factory setting):
• Type of protection:
• Battery check (control light)
• Water connection
Note
Major pressure differences between cold and hot water supply
should be avoided.
Special accessory, see spare parts fold-out page I.
• With the infrared remote control (ref.-no.: 36 206) the
following settings and changes could be conducted.
•
Adjust reception range (2" - 8")
•
Adjust tails time (0 - 10 s)
•
Set and activate continuous running (thermal
desinfection)
•
Switch off solenoid valve
•
Restore basic adjustment
•
Test mode
waterless simulation
=
•
Adjust safety stop (2 - 420 s)
•
Activate and set automatic flushing
• Special wrench (ref.-no.: 19 132) for dismounting flexible
hoses.
• Vandalism hampering concealed mixing spindle (ref.-
no.: 36 209).
• Base to increase faucet and sensor (ref.-no.: 36 210).
• Vandalism hampering anti twist plate (ref.-no.: 42 919).
The anti-twist plate is not combinable with base and not
useful for products with pop up waste set.
1
English
Disposal note
Dispose battery properly!
Installation
Flush pipe lines thoroughly!
1.9 L/min or 0.5 gpm/60 psi
7.25 psi
Mounting
14.5 - 72.5 psi
Refer to the dimensional drawings on fold out page I.
Lift rod (A) must be inserted into the faucet body during
145 psi
installation, see fold-out page II, Fig. [1].
232 psi
Mount faucet to basin, see Figs. [1] to [3].
158 °F
60 s
Fit pop-up drain (28 957), see fold-out page II, ensure that
1 s
flange of pop-up drain is sealed.
approx. 5"
IP 59 K
Connection
cold - RH
The cold water supply must be connected on the right and the
hot - LH
hot water supply on the left.
Screw adapter (B) by using the filter (C) or seal (B1) to the
thread adapter (D), see Fig. [4].
Connect adapter (D) to the angle stops (or other supply
points).
For the guarantee of a permanently error free operation
the installation of the enclosed adapters with filter
respectively non-return valve is mandatory necessary!
Open cold and hot-water supply and check connections
for leakage.
Operation
The infrared electronics sends invisible, pulsed light.
The infrared electronics is adjusted so that during approxima-
tion of the hands under the spout the watercourse is released.
Leave the hands the spout area the water course with stopped
after 1 s (factory setting).
The range of the sensor depends on the reflection
characteristics of the entering object.
Note:
For anonymous use we recommend the mounting of the
enclosed sticker.