Programming
20
Programming
a. Procedure
Activate this mode of operation as described in the
chapter "Modes of operation" and re-attach the
respective operating element.
For practical purposes, the shutter is in its upper limit
position.The shutter is moved downwards to the
desired position by long actuation. The shutter can be
stopped in between. The downward motion times are
totalled up and stored.
The return pulse (for slat adjustment, airing position for
roller blinds) begins when the shutter moves UP for the
first time. All subsequent motion times are added (UP
motion) or subtracted (DOWN motion) and stored as
an overall return pulse.
The max. return motion time is 25 s. The shutter is
stopped if this time is not reached or exceeded.
Before a return motion time is learned, a starting
motion time of at least 10 seconds must have been
learned beforehand.