Sirius SLT960 Instrucciones De Uso Y De Montaje página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
exceed 3 meters).
- Avoid abrupt direction changes.
- Use a 150mm constant diameter pipe for
the whole length.
- Use a standard approved material pipe.
FREE STANDING INSTALLATION
RECYCLING VERSION WITH INTERNAL MO-
TOR (FREE STANDING)
Caution:
Please make sure
the power cord
passes through
the specific openings
shown in fig. 2.
Mark the hood
fixing holes shown
in fig. 3 on the solid ceiling.
Drill the four holes by using an 8mm diame-
ter twist drill .
Insert the plastic anchors in the holes made.
Open the glass panels, by following the in-
structions given in the Operation Mode sec-
tion. Remove the grease filters by acting on
their handle.
Bring the appliance close to the ceiling and
push the power cord through the specific
pass Fig.2 A.
Secure the hood to the ceiling , by using the
screws supplied Fig. 13.
Perform the electric connection into the po-
wer supply metal box found inside the ap-
pliance .
Fit the charcoal filters ( to be purchased as
accessories ) as shown in Fig. 17.
Refit the grease filters and close the glass pa-
nels.
EXTRACTION VERSION WITH INTERNAL
MOTOR (FREE STANDING)
Rotate the motor , in order to prepare for the
air discharge on the upper side of the hood.
Open the glass panels, following the instruc-
tions given in the Operation Mode section,
and remove the grease filters.
Remove the 4 screws, as shown in figure 4.
Remove the lower metal sheet , as shown in
figure 5.
Remove the motor securing screws , as shown
in figure 6.
Open the hole in the centre of the hood upper
side (fig.7). Close the hole where the motor
was previously housed , by fixing the steel
plug using the four screws supplied (fig. 9).
Fit the motor on the hood top side, by using
the four screws previously removed (fig.10).
Connect the air exhaust pipe in the perfect
centre of the hood, as shown in Fig. 2 B.
Perform the same installation operations de-
scribed for the recycling version (Free stan-
ding).
The use of charcoal filters is not necessary
in this case.
EXTRACTION VERSION – EXTERNAL MO-
TOR (FREE STANDING)
The air outlet flange shall be fit in its specific
opening (fig. 8) found on the upper side of
the hood , as described below.
Open the hole in the centre of the hood upper
side (fig.7).
Fit the air-outlet flange by using the four
screws supplied (fig.8).
Connect the air exhaust pipe in the perfect
centre of the hood Fig. 2 B
Mark the hood fixing holes shown in fig. 3 on
the solid ceiling.
Drill the four holes by using an 8mm diame-
ter twist drill . Insert the plastic anchors in
the holes made .
Open the glass panels, following the instruc-
tions given in the Operation Mode section.
Remove the grease filters.
Bring the appliance close to the ceiling and
push the power cord through the specific
pass (fig.2)
Secure the hood to the ceiling , by tightening
the screws supplied
Perform the electric connection into the po-
wer supply metal box found inside the ap-
pliance and connect the remote motor cable
to its specific connector .
Refit the grease filter and close the glass pa-
nels.
The use of charcoal filters is not necessary in
this case.
13

Publicidad

Tabla de contenido
loading

Tabla de contenido