Problem
Cause
Torch body or
• Inadequate flow of coolant
power supply
overheated
• Welding current too high
• Coolant hose or liquid-cooled power cable
constricted or closed.
• Tungsten electrode loose
Tab. 7
Troubleshooting
11 Dismounting
12 Disposal
Dismounting may only be carried out by specialized personnel. Please make
sure that the shutdown procedures are strictly observed, before the dismounting
work begins. Ensure this also for the components integrated into the welding
system.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Disconnect the gas supply.
• Switch off the entire welding system.
• Pull the mains plug.
NOTE
• Observe the information given in section 8 Putting out of operation on
page EN-12.
1 Disconnect the TIG welding torches from the power supply.
For disposal, the local regulations, laws, provisions, standards and guidelines
must be observed. For the TIG welding torches to be properly disposed of, they
first must be dismounted.
 See 11 Dismounting on page EN-15
11 Dismounting
Solution
• Check that the re-circulating cooling
unit is working and performing
correctly
• Reduce
• Check the flow and replace if
necessary
• Tighten by means of torch cap
EN - 15